  • Page 1 FS-GIGA Quick Installation Guide...
  • Page 2 Product names, other than Positron's, mentioned herein may be trademarks and/or registered trademarks their respective companies. Disclaimer Notice Although Positron Access Solutions has made every effort to ensure the accuracy of the information contained herein, this document is subject to change. Positron Access Solutions...
  • Page 3: Table Of Contents

    Logging into the WEB UI .................... 10 2.2.2 System ........................11 Chapter 3 ............................12 Technical and Regulatory Specifications .................. 12 FS-GIGA Series Compact Remote Unit Technical Specifications ........13 Regulatory Compliance ....................15 Chapter 4 ............................18 Maintenance ..........................18 Filters ..........................19 Chapter 5 ............................
  • Page 4: Chapter 1

    FS-GIGA Quick Installation Guide Chapter 1 ______________________________________ FS-GIGA Positron Access Solutions Document 180-0147-001 R02...
  • Page 5: Introduction

    (RU) enables the transport of high quality, ultra-high bandwidth Carrier Ethernet business services and Metro/Macro Mobile backhaul services over bonded copper pairs. The FS-GIGA is compliant with the MEF CE 2.0 specification and provides up to 800 Mbps of bandwidth on 8 bonded VDSL2 pair with vectoring and 1 Gbps on Ethernet (Electrical and Optical).
  • Page 6 FS-GIGA Quick Installation Guide FS-GIGA-04 Remote Unit Front View FS-GIGA-04 Remote Unit Rear View FS-GIGA-08 Remote Unit Front View FS-GIGA-08 Remote Unit Rear View Positron Access Solutions Document 180-0147-001 R02...
  • Page 7 RJ-45 connector for secure SSH/CLI or WEB Interface MGMT access. Push-Button to temporarily override the Out-Of-Band configured FS-GIGA IP Address. When you push the LOCAL MGMT ENABLE button, a static Web page will LOCAL MGMT display the configured IP address. To access the static...
  • Page 8 A 2 position connector provides power to the unit for POWER local powering. The mating connector is capable of CONNECTOR supporting 12 to 18 gauge wires. 2 RJ-11 connectors for the FS-GIGA-04 Compact Remote Units Broadband 4 RJ-11 connectors for the FS-GIGA-08 Compact Remote Units...
  • Page 9: Web Management

    FS-GIGA Quick Installation Guide Chapter 2 ______________________________________ WEB Management Positron Access Solutions Document 180-0147-001 R02...
  • Page 10: Introduction

    FS-GIGA Quick Installation Guide Introduction The FS-GIGA can be securely managed by CLI or by WEB using a standard WEB browser like Internet Explorer, Chrome, Opera or Firefox. System Management 2.2.1 Logging into the WEB UI Enter the system's IP Address into the Web browser and you will see a screen...
  • Page 11: System

    FS-GIGA Quick Installation Guide 2.2.2 System The System monitor page provides a front panel representation of the FS-GIGA system. For complete detail on web management, please refer to the FS-GIGA User’s Guide. Positron Access Solutions Document 180-0147-001 R02...
  • Page 12: Chapter 3

    FS-GIGA Quick Installation Guide Chapter 3 ______________________________________ Technical and Regulatory Specifications Positron Access Solutions Document 180-0147-001 R02...
  • Page 13: Fs-Giga Series Compact Remote Unit Technical Specifications

    FS-GIGA Quick Installation Guide FS-GIGA Series Compact Remote Unit Technical Specifications System  Bandwidth on 8 VDSL2 bonded pairs (with vectoring): o Up to 800 Mbps Downstream o Up to 400 Mbps Symmetric  Resiliency: Carrier grade automatic pair failure protection ...
  • Page 14 • Sealing Current Mechanical  Chassis Dimensions: o FS-GIGA-08: 1.60" (41 mm)H x 8.5" (216 mm) W x 11.9" (302 mm) o FS-GIGA-08-OUT: 1.76" (45 mm) H x 8.5" (216 mm) W x 12.3" (312 mm) D o FS-GIGA-08-OUT-AC: 4.0" (102 mm) H x 11.5" (292 mm) W x 16.25"...
  • Page 15: Regulatory Compliance

    Regulatory Compliance FCC Declaration of Conformance The FS-GIGA models comply with part 15 of the FCC Rules. Operation is subject to the following two conditions (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 16 FS-GIGA Quick Installation Guide Les modèles FS-GIGA sont conformes à la norme NMB-003 d'Industrie Canada. Leur fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un...
  • Page 17 2014/30/EU and 2014/35/EU. Safety The FS-GIGA models conforms to IEC 60950-1/UL 60950-1/CSA C22.2 #60950- 1 standards. Les modèles FS-GIGA sont conformes aux normes IEC 60950-1/UL 60950- 1/CAN C22.2 #60950-1. Positron Access Solutions...
  • Page 18: Chapter 4

    FS-GIGA Quick Installation Guide Chapter 4 ______________________________________ Maintenance Positron Access Solutions Document 180-0147-001 R02...
  • Page 19: Filters

    Filters The FS-GIGA wall mount (outdoor) is fan-less and does not have filter. The FS-GIGA rackmount does have fans and filter. The filter for the FS-GIGA should be replaced every six months. Care should be taken when replacing filters to ensure collected dust on the filters does not enter into the equipment.
  • Page 20: Chapter 5

    FS-GIGA Quick Installation Guide Chapter 5 ______________________________________ Safety and Warnings Positron Access Solutions Document 180-0147-001 R02...
  • Page 21 A fuse panel must be provided as part of the building installation wiring in order to provide a UL required disconnect point. The FS-GIGA products accept 48Vdc for powering. The 48Vdc voltage range must be between -42.5Vdc to -56.5Vdc. Be careful when installing or modifying telephone lines; dangerous voltages can be present.
  • Page 22 Mounting of equipment in a rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. The Positron Multi Pair span interface is designed to coordinate with a standard 350 Vdc (230 Vdc in Europe) gas discharge tube protector. Carbon block protectors shall not be used.
  • Page 23 FS-GIGA Quick Installation Guide WARNING: The intra-building ports (Electrical Ethernet – RJ-45) of the equipment are suitable for connection to intra-building or unexposed wiring or cabling only. The intra-building ports of the equipment MUST NOT be metallically connected to interfaces which connect to the OSP or its wiring. These interfaces...
  • Page 24: Chapter 6

    FS-GIGA Quick Installation Guide Chapter 6 ______________________________________ Warranty and Customer Service Positron Access Solutions Document 180-0147-001 R02...
  • Page 25 FS-GIGA Quick Installation Guide Positron Access Solutions will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found on the Positron Access Solutions customer web portal: http://portal.positronaccess.com/...
  • Page 26: Chapter 7

    FS-GIGA Quick Installation Guide Chapter 7 ______________________________________ Positron Products Positron Access Solutions Document 180-0147-001 R02...
  • Page 27 Description FS-GIGA-08 FS-GIGA-08 rackmount with fans (8-pair VDSL) FS-GIGA-08-OUT FS-GIGA-08 wallmount (8-pair VDSL) FS-GIGA-PWR AC to -48v DC power supply for FS-GIGA rackmount FS-GIGA-FB19 19" brackets for FS-GIGA-08 rackmount FS-GIGA-FB23 23" brackets for FS-GIGA-08 rackmount FS-GIGA-FFL6 6-pack of air filters for FS-GIGA-08 rackmount...
  • Page 28: System Xdsl Error Information

    FS-GIGA Quick Installation Guide Appendix A: ______________________________________ System xDSL Error Information Positron Access Solutions Document 180-0147-001 R02...
  • Page 29 FS-GIGA Quick Installation Guide XSPAN Errors Description A CRC is a way of identifying if data was received error free. Transmitted data is divided into blocks that are appended with 1 or 2 CRC bytes that CRC Error are derived from the original data. The receiver re-computes the CRC bytes from the received data and if there is a mismatch, it signifies that there was a mismatch between the transmitted and received data.