Download Print this page

Goodman GPG13M Specifications page 23

2- to 5-ton c packaged gas/electric units 13 seer / 80% afue
Hide thumbs Also See for GPG13M:

Advertisement

w
d
iring
iagram
11.250 ±.125
SS-GPG13M
COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF GOODMAN MSP 824.01 WORKMANSHIP
5
— gPg1348-60m41
5.000 ±.125
YL
BK
BK
S
R
C
BL
BK
COMP
BK
CH OPTIONAL
CONNECTED AT L1, L2
PU
NOTE 3
BK
BR
CM
BK
PU
LS
BL
GR
C
L
G
N
RD
EM
T1
T2
T3
T4
T5
WH
NOTE 4
YL
YL
ALS
PU
PS
YL
PU
PU
YL
YL
Y
BR
WH
GR
RS
YL
SEE
3
6
NOTE 5
BL
YL
2
5
BL
1
4
PLF
PU
PU
YL
W. R.
(ALT.) HONEYWELL
PU
RD
WH
GAS VALVE
GAS VALVE
PU
MV
YL
BL
GV
GV
BL
MV
Y/Y2Y1
C R
W G
BL
TO THERMOSTAT
FS
RD
VM
IGN
OR
RD
PU
BL
YL
WH
BR
L1
SUPPLY VOLTAGE
208-230/1/60
CH
NOTE 3
C
T2
C
T1
R
1
C
COMP
S
H
RCCF C
F
CM
L
N
EM
VMR
4
2
VM
NOTE 2
2
3
1
TR
NOTE 7
NOTE 7
L1
IIC
IGN
FS
FS
T5
F
C
T4
EM
C
H
T3
T2 T1
1
3
D1
4
VMR
LS
5
ALS
RS
IIC
3
GV
6
PS
8
ECON
9
7
10
12
11
C
HPS
NOTE
5
6
5
PLF
3 2 1
Y/Y2
R
G
W
Y1
C
TO THERMOSTAT
INSTALLER/SERVICEMAN
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
EQUIP. STATUS
CHECK
STATUS LIGHT
ON
NORMAL OPERATION
-
NO POWER OR
CHECK INPUT POWER
OFF
INTERNAL CONTROL
CHECK FUSE ON CONTROL
FAULT
REPLACE CONTROL
IGNITION FAILURE
GAS FLOW
1 BLINK
OR
GAS PRESSURE
OPEN ROLLOUT
GAS VALVE
SWITCH
FLAME SENSOR
OR
FLAME ROLLOUT
OPEN AUX. LIMIT
BAD SWITCH
AUX. LIMIT OPEN
SWITCH
PRESSURE SWITCH
CHECK
2 BLINKS
OPEN
PRESSURE SWITCH
PRESSURE SWITCH CLOSED
CHECK
3 BLINKS
WITHOUT INDUCER ON
PRESSURE SWITCH
MAIN LIMIT OPEN
4 BLINKS
OPEN LIMIT SWITCH
BAD SWITCH
5 BLINKS
FALSE FLAME SENSED
STICKING GAS VALVE
COMPRESSOR
3 MIN. COMP.
6 BLINKS
OUTPUT DELAY
ANTI-CYCLE TIMER
4
RD
RD
PU
T1
T2
GND
BL
YL
C
L1
L2
BK
CH OPTIONAL
BK
POWER SUPPLY
BL
BK
BK
BK
PU
PU
208-230/1/60
SEE NOTE 6
PU
BK
BL/PK
NOTE 2
BL/PK
1
2
3
3
C
208
240
4
TR
1
2
24V
RD
BL
PU
YL
VMR
BL
BL
BL
RD
RD
RD
WH
RD
C22
T2
T1
P2
OR
150
135
P3
YL
MAX
AMP
3
FUSE
120
F1
RD
GR
RD
RD
BL
YL
YL
WH
OR RD BL
RD
RD
WH
RD
BL
SEE
IIC
BL
NOTE 7
GR
BL
BL
RD
YL
WH
PU
RCCF
F
H
C
RD
BR
YL
L2
COMPONENT LEGEND
FACTORY WIRING
ALS
AUXILLARY LIMIT SWITCH
LINE VOLTAGE
COMP
COMPRESSOR
LOW VOLTAGE
CM
CONDENSER MOTOR
OPTIONAL HIGH VOLTAGE
2
C
CONTACTOR
CH
CRANKCASE HEATER
EM
EVAPORATOR MOTOR
FIELD WIRING
F
FUSE
HIGH VOLTAGE
FS
FLAME SENSOR
LOW VOLTAGE
GND
EQUIPMENT GROUND
GV
GAS VALVE
WIRE CODE
IIC
INTEGRATED IGNITION CONTROL
BK BLACK
IGN
IGNITOR
BL BLUE
LS
LIMIT SWITCH
BR BROWN
PLF
FEMALE PLUG/CONNECTOR
GR GREEN
PS
PRESSURE SWITCH
OR ORANGE
RCCF
RUN CAPACITOR FOR COMPRESSOR/FAN
PK PINK
RS
ROLLOUT SWITCH
PU PURPLE
L2
RD RED
TR
TRANSFORMER
WH WHITE
VM
VENT MOTOR
YL YELLOW
VMR
VENT MOTOR RELAY
BL/PK BLUE/PINK
HPS
HIGH PRESSURE SWITCH
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
3. CRANKCASE HEATER NOT SUPPLIED ON ALL UNITS.
4. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING
SPEED AT MOTOR T4 AND T5 TERMINALS. CHANGE HEATING
SPEED AT MOTOR T1, T2 AND T3 TERMINALS.
COOLING SPEED (YELLOW WIRE)
HEATING SPEED (WHITE WIRE)
T4 - LOW SPEED
T1 - LOW SPEED
T5 - HIGH SPEED
T2 - MED. SPEED
T3 - HIGH SPEED
4
5. ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING
IN RETURN AIR COMPARMENT.
6. USE COOPER CONDUCTORS ONLY.
USE NEC CLASS 2 WIRE.
208-230/1/60
THERMOSTAT FIELD WIRING
2 STAGE COOLING WITH ECONOMIZER
NO ECONOMIZER
WH
WH
W
GR
G
GR
RD
RD
R
PU
YL
Y
YL
BL
C
BL
0140G01234 REV A
www.goodmanmfg.com
3
P
rodUct
RD
YL
W
G
R
Y1
Y2
C
2
s
Pecifications
ECN
REV
ZONE
0904067
A
-
THE
DRAWING TO BE INT
ACCORDANCE WITH A
DIMENSIONS ARE
23
UNLESS OTHERW
TOLERANCES
ANGLES ± 1.5°

Hide quick links:

Advertisement

loading