General Safety notes

Read and observe this technical description before commencing assembly and commissioning
work.
General
Depending on their type of protection power drive-converters can have live, bare, possibly moving
or rotating parts and a hot surface during operation.
There is a risk of death, serious injury or material damage if the required cover is removed
inadmissibly, if the equipment is not used for its intended purpose or if the equipment is installed or
operated incorrectly.
All installation, maintenance and repair work must only carried out by qualified specialist personnel
(observe IEC 60364 resp. CENELEC HD 384 or DIN VDE 0100 and IEC 60664 or DIN VDE 0110
and national accident prevention regulations e.g. BGV A2).
Qualified specialist personnel in the sense of these general notes on safety are persons who are
familiar with installation, assembly, commissioning and operation of this product and possess
qualifications appropriate for their work.
Use as specified
Power drive-converters are designed for installation into electrical systems or machines.
Commissioning (that means the beginning of use as specified) of a built-in drive-converter in a
machine is prohibited until it has been established that the machine or system complies with the
requirements of the EC-directive 2006/42/EG (machine-directive); observe EN 60204.
Commissioning (that means the beginning of use as specified) is permitted only if the latter
complies with the directives on EMC (2004/108/EG).
The drive-converters meet the standards of the low-voltage guideline 2006/95/EG. The harmonized
standards of the series EN 50178 combined with EN 60493-1 and EN 60146 / DIN VDE 0558 are
used for the drive-converters.
The technical data and information on connection conditions are provided on the rating plate and in
this technical description and must be observed under all circumstances.
Transport, Storage
The instructions for transport, storage and proper handling must be observed.
Damage established after delivery must be notified to the transport company immediately. If
necessary, the supplier must also be notified before the damaged inverter is put into operation.
Climatic conditions must be in accordance with EN 50178.
Installation
Installation and cooling must take place in accordance with the instructions in this technical
description.
Protect the power drive-converter against inadmissible conditions. Especially during transport and
handling do not bent components and/or do not change insulation distances. Avoid touching
electronic components and contacts.
The power drive-converter contains components that are sensitive to electrostatic burst and can be
damaged easily in case of inappropriate handling. Do not damage or destroy mechanically
electrical components by dismantling them into their individual components (risk for health and the
environment).