Jumper St3; Led; Dip-Switch - gefran KFM05a Instruction Manual

Asynchronous positioning motor with integrated frequency inverter and optional keypad
Table of Contents

Advertisement

3.1.5 Jumper ST3

With this jumper, the logic of the inputs is defined.
FRONT = 24V reference X7:1
BACK = GND reference X7:2, standard
Therewith, the inputs can be adjusted to any controller as described below. The default
configuration (BACK) corresponds to the connection examples.

3.1.6 LED

Status-LED
LED 4
LED 2
LED 1
LED 1 GREEN
LED 2 YELLOW
LED 3 RED
flashes
LED 4 GREEN
LED 5 YELLOW
on
off
LED 6 GREEN
on
off

3.1.7 DIP-Switch

Assignment of the DIP-Switch
S3.1
Modbus-Protocol
S3.2
Special function
S3.3
Fieldbus-controller active
S3.4
Option
S3.5
Configuration Analog Input 1
S3.6
Configuration Analog Input 2
Switch ON  Function active
Standard all OFF
Switch S3.5 und S3.6
Art.-No.: 918 111e
SIEI-AREG GmbH
Gottlieb-Daimler-Straße 17/3
74385 Pleidelsheim Germany
Fon: +49 7144 89736 0
LED 3
LED 6
LED 5
option
option
error
option
enable is set
power amplifier disabled
ready
reset is set
0 – 10 V / 0 – 20 mA
0 – 10 V / 0 – 20 mA
switch to the bottom
switch to the edge of the board
OFF  0 – 10 V voltage input
ON  0- 20 mA current input
Page 26 von 60
Rev. 09/14