Structure Of The Menu; Monitor (Displayed Value) - gefran KFM05a Instruction Manual

Asynchronous positioning motor with integrated frequency inverter and optional keypad
Table of Contents

Advertisement

Error memory:
In the menu item error memory, the last 10 errors can be displayed. To read the errors, they must
be readout the EEPROM. When "neu auslesen" is changed from 0 to 1, the readout is activated
and the last error will be displayed under "Feher 0".
The value before the point shows the time (in minutes) between the last reset to the occurrence of
the error (as an Hex-value).The value after the point is the error code. e.g. 08.EC h
Occurence of error
Error code

8.4 Structure of the menu

8.4.1 Monitor
Ausgangs-Spg.
Ausgangs-Frq.
Drehzahl
Ist-Position
Positions Nr.
Uzk-Spg.
Treiberspg.
C-Board Temp.
Motortemp.
Status
Digital Input
Analog1
Analog2
hex1hex2
Dip-Schalter
A-/E-Funktion
Betriebszeit
Art.-No.: 918 111e
SIEI-AREG GmbH
Gottlieb-Daimler-Straße 17/3
74385 Pleidelsheim Germany
Fon: +49 7144 89736 0
08 Minutes
EC
Warning motor temperature
(Displayed value)
(output voltage, Volt)
(output frequency, Hz)
(rotation frequency, 1/min)
(current position, Ink)
(position number)
(DC voltage, Volt)
(driver voltage, Volt)
(controllerboard temperature, °C [if probe available])
(motor temperature, °C [if motor has an KTY-probe])
(state drive [if 0 everything is ok])
(state of the digital inputs portpins at the µC)
(analog input 1, %)
(analog input 2, %)
(state Hex-switch, hex)
(state DIP-switch, binär)
(output and input functions, hex)
(operating hours, h)
Page 52 von 60
Fehlerspeicher
Menu
Fehler 2
Error Nr.
08.EC h
Time. error
Current state
Status:
Status:
0
0
Rev. 09/14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents