Overview Of The Plugs (Light Version); Mains Connection St 1; Control Connection St2 Digital Signals - gefran KFM05a Instruction Manual

Asynchronous positioning motor with integrated frequency inverter and optional keypad
Table of Contents

Advertisement

3. 2 Overview of the plugs (Light version)

3.2.1 Mains connection ST 1

Mains connection at ST 1 with connector of type PX0470 Bulgin and standard cable with A = 1,5
mm², e.g. H05VV-F1,5.
ST 1 Pin assignment:
L 1
Pin L
N
Pin N
PE
Pin PE
Choose a fuse according to the used cable, e.g. 16A for 1,5 mm² cable. Additionally the KFM05a
has to be grounded at the earth bolt with minimum 10 mm² cable.

3.2.2 Control connection ST2 digital signals

Control connection via ST 2 type P X0412 Bulgin.
Pin assignment:
Pin 1 :
Input 1 (24V 10mA)
Pin 2 :
Input 2 (24V 10mA)
Pin 3 :
Input 3 (24V 10mA)
Pin 4 :
Input 4 (24V 10mA)
Pin 5 :
Input 5 (24V 10mA) (Enable)
Pin 6 :
Common In
Pin 7 :
Output 1 (50mA)
Pin 8 :
Output 2 (50mA)
Pin 9 :
Output 3 (50mA)
Pin 10 :
Common Out
Pin 11 :
+24V external supply / PLC +UB based on reference on pin 6
Pin 12 :
+15V internal additional supply (100mA) based on reference on pin 6
Art.-No.: 918 111e
SIEI-AREG GmbH
Gottlieb-Daimler-Straße 17/3
74385 Pleidelsheim Germany
Fon: +49 7144 89736 0
Phase conductor
Neutral conductor
earth conductor
Page 30 von 60