Communication Baud Rate; System Configuration - GE EPM 3000P Instruction Manual

Three-phase digital volt/amps monitor
Table of Contents

Advertisement

CHAPTER 7
P
G
ROGRAMMING
The Global Meter Setup includes Functions 0 through 5 that control configuration and basic operation. Below is an
outline of GROUP 0 to assist in locating a feature. FUNCTION 3 System Configuration contains Switch PACKS with
various options, including open delta installation and communications.
T
7-1: GROUP 0 P
ABLE
ROGRAMMING
FUNCTION NUMBER
0.
1.
2.
3.
4.
5.
E.
7.1
G
0, F
ROUP
UNCTION
INTEGRATION INTERVAL: The time over which all instantaneous readings are averaged to obtain a maximum and
minimum demand. The Integration Interval is entered in seconds. When entering 15 minutes, enter: 0900 seconds.
To change the INTEGRATION INTERVAL, follow these steps:
NOTE: PRESS MAX/MIN/LIMITS, AT ANY TIME, TO CANCEL BEFORE STORING THE LAST DIGIT OR SWITCH.
0.
MAX
MIN
MAX/MIN
PRINT
VOLTS
AMPS
LIMITS
PROG
Step 1:
a. Enter Group Level of Programming Mode,
(see Chapter 6).
b. Press MAX/MIN/LIMITS until 0. appears in upper
display.
c. Press VOLTS to activate the GROUP.
00
3 _ _
MAX
MIN
MAX/MIN
PRINT
VOLTS
AMPS
LIMITS
PROG
Step 2:
a. Press VOLTS to begin Data Entry Sequence.
Three dashes appear in lower display.
b. Press PRINT/PROG for desired number.
Press PRINT/PROG once and the blank signifies zero.
Press PRINT/PROG twice and 1 appears.
c. Press VOLTS to store.
0: G
ROUP
LOBAL
F
ORMAT
FUNCTION
Integration Interval
Meter Address for Communication
Baud Rate for Communication

System Configuration

Relay 1 Set-up/Time Delay
Relay 2 Set-up/Time Delay
Exit Programming GROUP 0
0 - T
I
I
HE
NTEGRATION
NTERVAL
AC VOLTS
A B C
A B C
I
I I
I
I
I
N N N
B C A
AC AMPS
A B C N
LM1
LM2
PHASE
NEXT
AC VOLTS
A B C
A B C
I
I I
I
I
I
N N N
B C A
AC AMPS
A B C N
LM1
LM2
PHASE
NEXT
GE Industrial Systems
M
S
ETER
ETUP
00.
0 I0
MAX
MIN
MAX/MIN
PRINT
VOLTS
AMPS
LIMITS
PROG
00. appears in upper display, indicating current Group
and Function number.
Lower display indicates current Interval setting.
00.
300
MAX
MIN
MAX/MIN
PRINT
VOLTS
AMPS
LIMITS
PROG
Repeat this procedure until new Integration Interval is
entered.
When complete, lower display indicates new
Integration Interval.
See Chapter 12 to Exit.
AC VOLTS
A B C
A B C
I
I I
I
I
I
N N N
B C A
AC AMPS
A B C N
LM1
LM2
PHASE
NEXT
AC VOLTS
A B C
A B C
I
I I
I
I
I
N N N
B C A
AC AMPS
A B C N
LM1
LM2
PHASE
NEXT
22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Epm 3000p-f