Life Expectancy Of Major Parts; Replacement Of Batteries - Furuno FR-1500 MARK-3 Series User Manual

15" multi-color high-performance shipborne radar and arpa
Hide thumbs Also See for FR-1500 MARK-3 Series:
Table of Contents

Advertisement

Terminal strips
and plugs in
antenna unit
6 months
CRT and
to one
surrounding
year
components
Terminal strips,
sockets, earth
terminal

5.2 Life Expectancy of Major Parts

Parts
Type
Antenna motor D8G-571 (X-band) 42 rpm
D8G-571 (X-band) 24 rpm
Magnetron
MG5389, X-band, 6 kW
MAF1422B, X-band, 6 kW
MG4006, X-band, 6 kW
MAF1425B, X-band, 12 kW
MG4010, X-band, 12 kW
MG5436, X-band, 25 kW

5.3 Replacement of Batteries

The GYRO CONVERTER Board (option) and the RP Board have a battery. The battery for the RP
Board preserves data when the power is turned off, and its life is about five years. When the
battery voltage of the battery on the RD Board is low, NG (No Good) appears at the diagnostic test
for the RP board. When this happens, contact your dealer to request replacement of the battery.
Open antenna cover to
check terminal strip and plug
connections inside. Also
check the rubber gasket of
antenna covers for
deterioration.
High voltage at CRT and
surrounding components
attract dust in environment
which will cause poor
insulation. Ask your nearest
FURUNO representative or
dealer to clean internal
high-voltage components.
Check for loose
connections. Check contacts
and plugs for proper seating,
etc.
Life expectancy
Gears more than 10,000 h Wind load 100 kt
2,000 - 3,000 h
-5.2-
When closing antenna covers
in position, be careful not to
catch loose wires between
covers and unit.
If CRT anode rubber cap or
wire sheath is cracked, ask
your dealer to replace it. Wait
for at least 3 minutes until high
voltage components (CRT and
HV capacitors) discharge their
residual charges before
accessing them.
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-1505 mark-3Fr-1510 mark-3Fr-1525 mark-3

Table of Contents