ML Accessories EMPOWER3 Installation & Maintenance Manual

ML Accessories EMPOWER3 Installation & Maintenance Manual

Advertisement

INSTALLATION & MAINTENANCE MANUAL
EMPOWER3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EMPOWER3 and is the answer not in the manual?

Questions and answers

Summary of Contents for ML Accessories EMPOWER3

  • Page 1 INSTALLATION & MAINTENANCE MANUAL EMPOWER3...
  • Page 2 These instructions should be read carefully and retained after installation by the end user for future reference and maintenance. These instructions should be used to aid installation of the following product: EMPOWER3 SAFETY • This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and current Building Regulations.
  • Page 3 Please note the IP (Ingress Protection) rating of this luminaire when deciding the locatio installation Allow 50mm above and around the fitting for air dissipation (do not cover the fitting with i This product is Class II double insulated This product is IP20 rated INSTALLATION TALLATION •...
  • Page 4 Connect the luminaire to the mains supply via a suitable junction box ensuring that correct polarity observed: Live (brown) and Neutral (blue) (see Fig. 2) Fig. 2 • Connect the battery to the inverter via the plug and socket provided, ensuring correct polarity is observed Connect the battery to the inverter via the plug and socket provided, ensuring that correct polarity is •...
  • Page 5 ML Accessories does not accept responsibility for any installation costs associated with the replacement product. Your statutory rights are not...
  • Page 6 TESTING FOR EMERGENCY LUMINAIRES Recommended routine test procedure in accordance with BS5266 • Daily check – check LED charge indicator is illuminated • Monthly functional test - simulate a mains supply failure for approx. 30 seconds by operation of key switch or switching off circuit breaker. Ensure normal supply is restored after test and ensure charge indicator is illuminated •...
  • Page 7 TEST RECORD SHEET SIGNED DATE INITIAL COMMISSIONING 3 HOUR TEST FIRST YEAR SECOND YEAR THIRD YEAR FOURTH YEAR FIFTH YEAR MONTH TEST SIGNED DATE SIGNED DATE SIGNED DATE SIGNED DATE SIGNED DATE FUNCTIONAL FUNCTIONAL FUNCTIONAL FUNCTIONAL FUNCTIONAL FUNCTIONAL FUNCTIONAL FUNCTIONAL FUNCTIONAL FUNCTIONAL FUNCTIONAL...
  • Page 8 INTERNAT CONTACT D INTERNATIONAL CONTACT DETAILS 60°C ML Accessories Limited LU5 4LT www.mlaccessories.co.uk AVSEP21_V2...

Table of Contents