SYSTEM OPERATION
Cooling Mode Speed Selection
To change the main blower speed in COOLING mode, fol-
low the following steps:
1. Press the left or right switch until LED displays "AC1
"(for single stage COOLING) or "AC2 "(for two-stage
COOLING). Press the center switch and LED will dis-
play the selected speed number as Fxx (xx: Blower
speed number from 1 to 9).
2. The control will rotate available speed number every
time left/right switches are pressed. All 9 speeds are
available for both Single and Two Stage cooling.
3. When the center switch is pressed, the current dis-
played speed will be selected, and control will apply
the newly selected speed in next cooling call.
THERMOSTAT CALL
Y/Y1
Single-Stage Cooling Speed Table for 2 Stage IFC
THERMOSTAT CALL
Y2
Two-Stage Cooling Speed Table for 2 Stage IFC
Furnace Shutdown
1. Set the thermostat to the lowest setting. The inte-
grated control will close the gas valve and extinguish
flame. Following a 15 second delay, the induced draft
blower will be de-energized. After the blower off delay
time expires, the blower de-energizes.
2. Remove the burner compartment door and move the
furnace gas valve manual control to the OFF position.
3. Close the manual gas shutoff valve external to the
furnace.
4. Replace the burner compartment door.