IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
1.8 Propane gas installation
¡ The propane gas tank must be equipped with its own
high pressure regulator. In addition, the regulator sup-
plied with this unit must also be used.
¡ The appliance is shipped from the factory for use with
natural gas. It must be converted for use with propane.
A qualified technician or certified installer must do the
conversion.
¡ For use with propane the appliance must be converted
per the LP conversion instructions.
→  "Conversion to LP gas", Page 13
For Massachusetts installations
¡ Installation must be performed by a qualified or li-
censed contractor, plumber or gas fitter qualified or li-
censed by the state, province or region where this ap-
pliance is being installed.
¡ Shut-off valve must be a "T" handle gas cock.
¡ Flexible gas connector must not be longer than
36 inches.
Installer - show the owner where the gas shut-off valve is
located.
1.9 Ventilation recommendations
We strongly recommend the installation of a ventilation
hood above this appliance.
The hood must be installed according to instructions fur-
nished with the hood.
WARNING
The appliance should not be installed with a ventilation
system that blows air downward toward the burners. This
type of ventilation system may cause ignition and combus-
tion problems with the gas cooking appliance resulting in
personal injury or unintended operation.
1.10 High altitude installation
This appliance has been tested for operation up to an alti-
tude of 10,100 ft (3,080 m) elevation above sea level.
For altitudes above 2,000 ft (610 m) elevation above sea
level, burner flame adjustments may be necessary.
Burners should be checked at the lowest setting, if the
flame is not stable the simmer should be increased until
the flame is stable. This can be done by adjusting the by-
pass screw in the valve. If flame performance is satisfac-
6
tory, adjustment will not be required. It is required that a
certified professional make the high altitude adjustments
during installation.
1.11 State of California Proposition 65
Warnings
This product may contain a chemical known to the State
of California, which can cause cancer or reproductive
harm. Therefore, the packaging of your product may bear
the following label as required by California: