9 ] Simulation And Self Diagnosics; 9 ] Simulation And Self Diagnostics; Simulation - Sharp Z-21 Service Manual

Table of Contents

Advertisement

[9] SIMULATION AND SELF DIAG

1. Simulation

Simulation No.
@
0
@
1
@
2
@
3
Simulations 0 ∼ 3 cannot be executed in the Z-21.
@
By installing the operation panel of the Z-26 to the Z-21, simulations 0 ∼ 3 can be executed in the Z-21.
1-1. Execution procedure
Simulation No. and function
0: Total counter read
1: Drum counter read
2: Total counter write
Content
Total counter read
Drum counter read
Total counter write
Drum counter write
Drum counter clear
Total counter read (Z-21 only)
Lead edge image loss adjustment
Copy lamp normal range brightness adjustment
AE gain setting (auto)
AE gain setting (manual)
Auto exposure correction
Short the main PWB pins (JP208-JP206), turn on the power, and "0" will be displayed.
Press the PRINT key, and the total counter content is displayed on the copy quantity display
from the digit of ten thousands to the digit of one in sequence. (This is repeated until the end of
the simulation.)
To terminate total counter read, press the EXPOSURE key, and the mode is changed to the
standby mode for the next simulation (1, 2, or 3).
To terminate the simulation, release the short of the PWB, and turn off and then on the power.
Short the main PWB pins (JP208-JP206), turn on the power, and "0" will be displayed. Then
press the copy quantity set key to display "1."
Press the PRINT key, and the Drum counter content is displayed on the copy quantity display
from the digit of ten thousands to the digit of one in sequence. (This is repeated until the end of
the simulation.)
To terminate drum counter read, press the EXPOSURE key, and the mode is changed to the
standby mode for the next simulation (2, 3, or 0).
To terminate the simulation, release the short of the PWB, and turn off and then on the power.
Short the main PWB pins (JP208-JP206), turn on the power, and "0" will be displayed. Then
press the copy quantity set key to display "2."
Service
Service
Service
Service
Service
Service
User
Content
Entering the simulation mode.
Functional description
End of the simulation
Entering the simulation mode
Execution of the function
End of the simulation
Entering the simulation mode
Execution of the function
– 22 –
Use division

Advertisement