Remote Control
Remote Control, cont'd
The SW RGBHV A Series switchers can be remotely controlled via the switcher's
rear panel Remote connector (figure 4-1). Remote control devices can be:
Three remote control methods are available:
Figure 4-1 — Remote connector pinout
The RS-232 protocol of the rear panel RS-232/Remote connector is as follows:
• 9600 baud
• 1 stop bit
For RS-232 control and IR control, use a control cable with only pins 2, 3, and 5
connected. Otherwise, either cut the wires to the other pins in hard-shelled
connectors or remove the unneeded pins from molded plugs. See "Simple
Instruction Set", for definitions of the SIS commands and "Windows
Control Program"for details on how to install and use the control software.
For contact closure, use a control cable with pins 2 and 3 NOT connected.
Otherwise, either cut the wires to these pins in hard-shelled connectors or remove
these pins from molded plugs. See "Contact Closure", for information on how to
construct a remote contact closure device.

Simple Instruction Set

Host-to-switcher instructions

SIS commands consist of one or more characters per field. No special characters
are required to begin or end a command character sequence. When a command is
valid, the switcher executes the command and sends a response to the host device.
All responses, from the switcher to the host, end with a carriage return and a line
feed (CR/LF =
is one or more characters.
4-2
SW RGBHV Series Switchers • Remote Control
A host device (such as a computer or control system)
An IR 102 Remote Control Kit
A contact closure device such as an Extron KP 6 Keypad Control or a locally-
constructed device.
Extron's Simple Instruction Set
Extron's Windows
®
-based control program
Contact closure
Pin
RS-232
5
1
1
2
TX
9
6
3
RX
Female
4
1
5
5
Gnd
6
7
6
9
Male
8
9
• No parity
• No flow control
The cable used to connect the Remote port to a computer, control system,
contact closure device, or IR control kit may need to be modified by removing
pins or cutting wires. If unneeded pins are connected, the switcher may hang
up.
), which signals the end of the response character string. A string
Contact closure
Function
In #1
Input #1
Transmit data (-)
Receive data (+)
In #2
Input #2
Gnd
Signal ground
In #3
Input #3
In #4
Input #4
In #5
Input #5
In #6
Input #6
®
-Based