Advertisement

Quick Links

Distributed b
y:
Distributed by:
S.I.A.T.A Asia Pacific Pte Ltd
37 Tannery Lane
#06-08 Tannery House
Singapore 347790
Tel: +65 6741 2994 • Fax: +65 6741 2995
www.siata.com.sg
USE AND MAINTENANCE MANUAL
AQUA CUBIC PLUS
Aqua Cubic Plus
-
1/27

Advertisement

Table of Contents
loading

Summary of Contents for Pentair SIATA AQUA CUBIC PLUS

  • Page 1 Distributed b Distributed by: S.I.A.T.A Asia Pacific Pte Ltd 37 Tannery Lane #06-08 Tannery House Singapore 347790 Tel: +65 6741 2994 • Fax: +65 6741 2995 www.siata.com.sg USE AND MAINTENANCE MANUAL AQUA CUBIC PLUS Aqua Cubic Plus 1/27...
  • Page 2 EC DECLARATION OF CONFORMITY S.I.A.T.A. S.r.l. Producer Declares that the following material: AC-PLUS2/05 Description AQUA CUBIC PLUS Conforms to the essential pre-requisites of the following DIRECTIVES:  Electromagnetic Compatibility 89/336/CEE, 93/68/CEE  Low Voltage 73/23/CEE, 93/68/CEE The fulfilment of the following regulations has been verified: EN 50081-1 General Regulation on Emissions - part 1 residential, commercial and light industry environment EN 50082-1 General Regulation on Immunity - part 1:residential, commercial and light...
  • Page 3: Table Of Contents

    Index ..........................5 1 – INTRODUCTION 2 – TECHNICAL DATA ........................6 ................7 3 – EXPLANATION OF THE LEDs AND OF THE KEYS ................. 7 4 – STATES OF VISUALISATION OF THE DISPLAY 5 – GENERAL ............................. 8 5.1 – Packaging and storage ........................8 5.2 –...
  • Page 4 7.5 – … one column is not working ? ....................... 24 Appendix A ............................25 Appendix B ............................26 Appendix C ............................27 Aqua Cubic Plus 4/27...
  • Page 5: Introduction

    1 – INTRODUCTION Aqua Cubic Plus is a controller dedicated to the realisation of water softening systems working on the principle of the ionic exchange of the resins. The systems can be produced according to the following operative modalities: - one single column; - one duplex column;...
  • Page 6: Technical Data

    2 – TECHNICAL DATA Fig. 1 Supply voltage 230 Vac  10% Network frequency 50 Hz  3% Power absorbed 30 VA Operative temperature 0° C – 55° C Class of protection IP65 Protection from disturbances ICE 65 Trial class 4 ( 3000 V ) Reading scale 0 –...
  • Page 7: Explanation Of The Leds And Of The Keys

    3 – EXPLANATION OF THE LEDs AND OF THE KEYS Tab. 1 – Functionality of the LEDs Meaning A SERVICE Column A is in service B SERVICE Column B is in service STAND-BY Request for regeneration (this will be carried out at the programmed time) REGEN Regeneration in progress...
  • Page 8: General

    5 – GENERAL The installation of the controller must be carried out by qualified personnel; the installation procedures must be carried out when the controller is disconnected from the electricity supply Packaging and storage 5.1 – The packaging consists of a cardboard box with a label identifying the product, carrying the following information: name of producer and PN producer AC-PLUS2/05;...
  • Page 9: Protection Devices

    Protection devices 5.4 – The appliance is protected from current overloads by a 0.6A supply retardant fuse which is assembled on the front panel. It is also protected against disturbances originating from the electricity supply by filters mounted inside the controller.
  • Page 10: Ppp0 - One Single Column

    6.2.1 – PPP0 – One single column 6.2.1.a – Operative characteristics This modality has been designed to resolve emergency cases if Aqua Cubic Plus is used in a duplex system and one column stops working, it is possible to use the other column singularly and to continue to provide treated water to the user (see par.
  • Page 11: Ppp2 - Two Alternated Single Columns

    FLAG not used 3 C P 0 PROGRAM 3 C P FLAG not used 0 d P 0 PROGRAM 0 d P Enables the start-up and the stop of the manual regeneration with the keys 1 1 d P 1 PROGRAM 1 d P and 0...
  • Page 12 6.2.2.b – Programming of the flags Tab. 8 shows the options available for the modality PPP2 Tab. 8 – Selection of the operative modality two alternated single columns PPP2  Display Operative state / Visualised data FLAG State of access to the selection of the operative modality PROGRAM P 0 0 0 Visualisation of the current operative modality (x = 0, 2, 4, A)
  • Page 13: Ppp4 - One Duplex Column

    6.2.2.c – List of codes to be programmed For the programming of the codes, see par. 6.3. In this modality it is advisable to programme the following codes: Tab. 9 – Table of the codes in the modality of two alternated single columns PPP2 Code Meaning Setting of the value of the capacity of the resins exchange...
  • Page 14 6.2.3.b – Programming of the flags Tab. 11 shows the options available for the modality PPP4 Tab. 11 – Selection of the operative modality one duplex column PPP4  Display Operative state / Visualised data FLAG State of access to the selection of the operative modality PROGRAM P 0 0 0 Visualisation of the current operative modality (x = 0, 2, 4, A)
  • Page 15: Pppa - Two Single Columns In Parallel

    Tab. 12 – Table of the modality one duplex column PPP4 Code Meaning Setting of the value of the capacity of the resins exchange Setting of the volume of resin and of the percentage of reserve of the column A Setting of the litre counter divider (prescaler) Setting of the regeneration cycle ( stop times) Setting of the hardness value...
  • Page 16 The new programming is operative after the next regeneration 2 / + 2 C P 1 2 C P FLAG not used PROGRAM 3 C P 0 3 C P Disables the check of the reserve PROGRAM 0 d P 0 0 d P Enables the control of the reserve PROGRAM...
  • Page 17: Programming Codes

    6.3 – Programming codes The work parameters necessary for the correct functioning of Aqua Cubic Plus are inputted with access via the programming codes, under which the parameters are grouped with a precise function of the controller. The following paragraphs illustrate how the programming codes are accessed and their use. 6.3.1 –...
  • Page 18 Code  Display Meaning visualised Time of regeneration; to change the flashing numbers use the key 2/+, ENTER x x x x press PROGRAM to pass from the minutes to the hours. P 0 1 2 Days of interval between two regenerations ( from 1 to 30) PROGRAM P - x x (programming with no effect )
  • Page 19: Programming Of The Reserve

    6.4 – Programming of the reserve Aqua Cubic Plus allows for the volume of treatable water to be controlled, putting it into ratio with a possible reserve value. This is programmed via the code 100 (see par. 6.3) and expresses the percentage of the total volume available which must be held in reserve.
  • Page 20: Calculation Of The Capacity Of A System

    Tab.18 – Table of the pre-programmed litre counter dividers and range of flow admissible Prescaler impulses/litre Minimum load of the flow (lit/min) Maximum load of the flow (lit/min) 14/01 4/10 1500 2/10 3000 1/10 6000 4/100 9999 2/100 9999 1/100 9999 4/1000 9999...
  • Page 21: Putting Into Service

    6.8 Putting into service IMPORTANT Always remember to key in the code 220 (ref. par. 6.3) after the various phases of programming before Aqua Cubic Plus has been put into service. Always remember that before carrying out operations on the keypad of Aqua Cubic Plus, it must be checked that the cams of the distributors are on the position of stroke end ( except when they are in regeneration, a condition which may be verified via the led Regen), and that any unused limit switch entries are closed with a connector bridge.
  • Page 22: Management Of The Cylinder Dimensions

    Fig. 2 6.10 – Management of the cylinder dimensions Aqua Cubic Plus allows for a system to be formed consisting of two columns, that is using two columns, each connected to a SIATA valve and therefore to a cylinder containing the resins.. The programming of the capacity dimensions of the cylinders may be carried out all at once, if they are the same, or separately, if the cylinders have different capacities.
  • Page 23: Modifying The Programming During Service, The Flag 2Cp

    6.11 –Modifying the programming during service, the flag 2CP As already explained in par. 6.3, Aqua Cubic Plus calculates the volume of water which can be treated using the values of hardness of the water, the capacity of ionic exchange of the resins and the quantity of resin used. The calculation is carried out automatically at the end of the programming of the hardness (code 010), or otherwise may also be carried out keying in the code 211.
  • Page 24: There Is No Current To The Utilisers

    7.3 - ... there is no current to the utilisers? Remember that Aqua Cubic Plus does not supply current to the exits, but only closures that the operator must wire at his own discretion, check that the wiring is correct, that the conductors are correctly inserted into the terminals and that these are closed correctly;...
  • Page 25 Appendix A Aqua Cubic Plus 25/27...
  • Page 26 Appendix B Aqua Cubic Plus 26/27...
  • Page 27 Appendix C Distributed b Distributed by: S.I.A.T.A Asia Pacific Pte Ltd 37 Tannery Lane #06-08 Tannery House Singapore 347790 Tel: +65 6741 2994 • Fax: +65 6741 2995 www.siata.com.sg Aqua Cubic Plus 27/27...

This manual is also suitable for:

Ac-plus2/05

Table of Contents