Stage Two — Install the Wallplates and MLC 104 IP Plus
N The installation must conform to national and
local electrical codes, and UL requirements.
Refer to the devices' user manuals for details.
1. Install mud rings
N These devices can be installed using the supplied
mud ring or a wall box. If installing a box, allow
enough depth for the plate, and the cables. The box
should be at least 2.5" (6.4 cm) deep to
accommodate the connectors and cables.
If a suitable wall box is already installed, follow
step 2 onwards.
a. Mark the holes for the mud rings.
T Use a level when marking the holes.
b. Cut out the material from the marked area.
c. Insert the mud ring into the opening. The mud ring's
rear connectors should fit easily into the opening. Bend
over the mud ring doglegs and secure with the screws
provided.
Repeat steps a to c for all the transmitters needing to be
installed.
d. At the desired location repeat steps a to c for the larger
MLC 104 IP Plus mud ring
2-10
PoleVault Systems Installation • Installation — Stage 2
1c Insert the mud ring.
NOTE
Rotate the dogleg out of
the way to insert the
mud ring into the wall.
Dogleg
1d Features for mud ring installation
Wall
Dogleg
Screw
Equipment Mounting
Holes
Surface Mounting
Hole