Digital Sync Validation Processing (DSVP™) (CrossPoint) —
In critical environments or unmanned, remote locations, it may be vital to
know that sources are active and switching. Extron's DSVP confirms that
input sources are active by scanning all sync inputs for active signals. DSVP
provides instantaneous frequency feedback for composite sync or separate
horizontal and vertical sync signals via the switcher's serial ports or Ethernet
port. The frequency information can be displayed on any control system
or in a Windows
-based control program on a local-area network (LAN) or
®
Internet (IP) connection (figure 1-3).
Input # 01
Signal: PRESENT
Sync Type: H&V
Vertical Freq.: 60 Hz
Horz Freq.: 31.5 kHz
Input Horz. Vert.
01
31.50
60.00
02
31.50
60.00
03
31.50
60.00
04
48.01
67.50
05
48.01
67.50
06
48.01
67.50
07
48.01
67.50
08
61.55
72.00
09
61.55
72.00
10
61.55
72.00
11
61.55
72.00
12
61.55
72.00
Figure 1-3 — DSVP data display
Rooming — Each switcher can be programmed to group multiple outputs to
specific "rooms", allowing them to have their own presets.
Switching flexibility — Provides individually buffered, independent matrix
switched outputs with audio follow and audio breakaway for audio models.
Tie any input to any or all outputs
Quick multiple tie — Multiple inputs can be switched to multiple outputs
simultaneously. This allows all displays (outputs) to change from source to
source at the same time.
Audio follow — Audio can be switched with its corresponding video input
via front panel control or under Ethernet or serial port remote control.
Audio breakaway — Audio can be broken away from its corresponding
video signal. This feature allows any audio signal to be selected with any
video signal simultaneously to one or all outputs in any combination. Audio
breakaway switching can be done via front panel control or under Ethernet or
serial port remote control.
CrossPoint / MAV Matrix Switchers • Introduction
MATRIX INPUT STATUS
Input # 01
Input # 02
Input # 03
Input # 04
Signal: PRESENT
Signal: PRESENT
Signal: PRESENT
Signal: PRESENT
Sync Type: H&V
Sync Type: H&V
Sync Type: H&V
Sync Type: H&V
Vertical Freq.: 60 Hz
Vertical Freq.: 60 Hz
Vertical Freq.: 60 Hz
Vertical Freq.: 60 Hz
Horz Freq.: 31.5 kHz
Horz Freq.: 31.5 kHz
Horz Freq.: 31.5 kHz
Horz Freq.: 31.5 kHz
Input # 05
Input # 06
Input # 07
Input # 08
Signal: PRESENT
Signal: PRESENT
Signal: PRESENT
Signal: PRESENT
Sync Type: H&V
Sync Type: H&V
Sync Type: H&V
Sync Type: H&V
Vertical Freq.: 60 Hz
Vertical Freq.: 60 Hz
Vertical Freq.: 60 Hz
Vertical Freq.: 60 Hz
Horz Freq.: 31.5 kHz
Horz Freq.: 31.5 kHz
Horz Freq.: 31.5 kHz
Horz Freq.: 31.5 kHz
Input # 09
Input # 10
Input # 11
Input # 12
Signal: PRESENT
Signal: PRESENT
Signal: PRESENT
Signal: PRESENT
Sync Type: H&V
Sync Type: H&V
Sync Type: H&V
Sync Type: H&V
Vertical Freq.: 60 Hz
Vertical Freq.: 60 Hz
Vertical Freq.: 60 Hz
Vertical Freq.: 60 Hz
Horz Freq.: 31.5 kHz
Horz Freq.: 31.5 kHz
Horz Freq.: 31.5 kHz
Horz Freq.: 31.5 kHz
Sample control system panel
OR
Windows-based control program
1-9