5-5. E-MOUNT LENS ADJUSTMENT
Equipment and Tools
• Personal Computer (See Note 1, 2)
• HASP key (SeusEX)
• Micro USB cable
• Lens adjustment program (E-Mount Lens Adjustment.zip)
• Flange back adjustment jig
• FB adjustment chart (10 mm)
• Siemens star chart
• Camera (ILCE-5000, ILCE-6300) (See Note 3)
Note 1: Personal computer must have the condition that Windows 7
runs normally and USB is connectable.
Note 2: The Excel must be installed in the PC.
Note 3: When performing the focus shift adjustment, use the ILCE-
6300. When performing the other items, use the ILCE-5000.
5-5-1. Preparations
Set the equipment and the lens to be tested as shown below.
When the subject is a siemens star chart
Siemens star
chart
When the subject is a flange back adjustment jig
Flange back
adjustment jig
Flange back
adjustment jig
FB adjustment
chart
Personal
computer
USB cable
HASP key
To USB connector
Siemens star
Image sensor
chart
position mark
370 mm
Lens to be
tested
Within 10 mm
Lens to be tested
AC adaptor
Lens to
be tested
Camera
To USB
connector
Tripod
To tripod
screw
(1) Installation
For adjustment of the SEL1635GM, prepare a version 1.4.1.6 or high-
er of the lens adjustment program (E-Mount Lens Adjustment.zip).
Note: Perform the installation by administrator privileges.
Do not change the installation folder.

Procedure of Installation

1. Download the lens adjustment program (E-Mount Lens Adjust-
ment.zip).
2. Double click the setup.exe file.
3. The installer screen appears, then click the [Next] button.
4. The folder select screen appears, then select the installing user
and click the [Next] button.
AC
Everyone: The application will be installed for all users.
Just me: The application will only be installed for the current user.