SEL1635GM
5. Align the plane mirror with the center projected image on the screen, and confirm again that the reflected light illuminates the center of the
lens to be tested. If the reflected light position is deviated, re-adjust the lens projector position.
6. Select "Open" from the iris selection menu, and click [Iris].
Iris setting: Open
7. Rotate the zooming ring of the lens to be tested and set the focal length to the arbitrary position.
Note 2: This lens is not power zoom, do not use the following zoom operation.
Zoom operation
8. Select "JOG" from the focus menu.
Check off
Not used this section
Use this section
– Continued on next page –