Time data
Table 3.3.6 lists times displayed and printed out in conjunction with the source of time
data.
Times displayed and printed
Time in DSC display
Time in DSC self-test result display
Time stamp on DSC self-test result
Time stamp on communication log
file
Time stamp at transmission
Time stamp at reception
Time on IB-581
Time on IB-583
6. PRINT OUT
The automatic printing mode is switched on or off. Transmitted message, received
message and test result are printed out. To print out the messages and test result
manually, press [8 Print].
XMTD CALL
Automatic printing of transmitted DSC message is switched on or off.
RCVD CALL
Automatic printing of received DSC message is switched on or off.
DAILY TEST
Automatic printing of daily test result is switched on or off.
Data to be used (source)
Time included in position data
Real Time Clock (RTC) on
T-CPU board
RTC from FS-1570/2570
3-24
3.3 DSC SETUP
Table 3.3.6 Time data
Remarks
The real time clock on
T-CPU board is reset
by ZDA at power on.
RTC on IB-583/581 is
reset by RTC from
FS-1570/2570 every
time IB-583/581 is
turned on.