Remote Memory Select Inputs For 28-Pin Receptacle (If Present) - Miller Dynasty 400 Owner's Manual

Ce and non-ce models
Hide thumbs Also See for Dynasty 400:
Table of Contents

Advertisement

3
Input
4
Output
5
Output
6
Output
7
Output
8
Output
9
Output
11
Output
12
Output
19
Input
21
Input
22
Input
25
Input
A. User Controlled Automation Mode (Pin 25 Connected To Pin 8) Automation 2
26
Input
27
Input
14
28
Input
20
All other pins not used.
5-7.

Remote Memory Select Inputs For 28-Pin Receptacle (If Present)

28-Pin Receptacle RC28
2-5. Remote Memory Select Inputs (For 28-Pin Receptacle If Present)
3
8
14
20
25
28
Socket Designations: 0 = No Connection / 1 = Connected To Ground (Pin 8)
Complete Parts List is available at www.MillerWelds.com
Gas Control
Valid Arc Indication
Scaled Actual Welding
Voltage
Scaled Actual Welding
Amperage
+15 volts DC
Reference Pin
Valid Arc Indication
Reference
Control Reference
Welders Chassis
High Frequency Arc Start
Disable
Isolated EN Amperage
Common
Isolated EN Amperage
Command
A complete Parts List is available at www.MillerWelds.com
User Controlled Automa-
tion Select
Isolated EP Amperage
Command
Isolated EP Amperage
2
3
1
Common
8
7
6
5
4
AC Waveform Generation
13
9
12 11
10
15
19
18
17
16
24 23
22
21
25
27
28
26
1
4
9
15
21
26
This input is used to control the gas flow outside the settings of the preflow
and/or postflow set on the machine. Connection to pin 8 turns on gas.
Paired with Pin 9. This output is used to signal external fixtures that the ma-
chine has detected a valid arc. Pin is closed to pin 9 when the output is on
and there is less than 65 load volts. Electrical specifications: Open collector
transistor maximum values 27 volts DC peak @ 75mA. See Section 5-5 .
+1 volt DC per 10 volts of output w/respect to pin 11.
+1 volt DC per 100 amperes of output w/respect to pin 11.
With respect to pin 11 (Pin A of 14 pin).
This pin is the signal reference for pins 1, 2, 3, 10, 15, 16.
Paired with Pin 4. Connect to user's external voltage supply common. See
Section 5-5 .
For pins 5 and 6.
Earth ground. Connected only if common potentials are needed between user
equipment and the welder.
Disables the arc starter from being activated when connected to pin 8.
Paired with Pin 22.
Paired with pin 21. Sets output amperage value for a Maxstar and the EN am-
perage value for a Dynasty. Value should be between 0.3 to 10V correspond-
ing to the minimum to maximum of the machine.
Connect to pin 8 to activate this mode.
(Dynasty models only) Paired with Pin 27. Sets EP (cleaning) output amper-
age value. Value should be between 0.3 to 10 volts corresponding to the mini-
mum to maximum of the machine.
(Dynasty models only) Paired with Pin 26.
(Dynasty models only) User controlled polarity (EN or EP), frequency (20-400
HZ) and balance of an AC waveform. When this pin is not connected to pin 8
the weld output is EN. When this pin is connected to pin 8 the weld output is
EP. Alternating between connection and disconnection at different intervals
creates the frequency and balance of the waveform.
Function
Pin 10
Off
Memory 1
Memory 2
Memory 3
Memory 4
Memory 5
Memory 6
Memory 7
804746-B / 21816-A
Pin 16
0
0
0
0
0
1
0
1
1
0
1
0
1
1
1
1
OM-275857 Page 27
Pin 15
0
1
0
1
0
1
0
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynasty 800Maxstar 400Maxstar 800

Table of Contents