B. Connecting Single-Phase Input Power
B. Connecting 1-Phase Input Power
3
tools/
flathead
knife
steelbrush
heavy-duty workclamp
light-duty workclamp
A complete Parts List is available at www.MillerWelds.com
Complete Parts List is available at www.MillerWelds.com
1
8
10
7
9
L1
L2
6
philips head
wrench
nutdriver
wirecutter
=GND/PE Earth Ground
1
1
2
3
6
4
5
crescent wrench
chippinghammer
frontcutter
Installation must meet all National
and Local Codes—have only quali-
fied persons make this installation.
Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit. Follow es-
tablished
procedures
the installation and removal of
lockout/tagout devices.
Always connect green or green/
yellow
conductor
grounding terminal first, and never
to a line terminal.
The Auto-Line circuitry in this unit auto-
matically adapts the power source to
the primary voltage being applied.
Check input voltage available at site.
This unit can be connected to any input
power between 208 and 575 VAC with-
out removing cover to relink the power
source.
See rating label on unit and check input volt-
age available at site.
1 Black And White Input Conductor (L1
And L2)
2 Red Input Conductor
3 Green
Or
Green/Yellow
Conductor
4 Insulation Sleeving
5 Electrical Tape
Insulate and isolate red conductor as shown.
6 Input Power Cord
7 Disconnect Device (switch shown in the
OFF position)
8 Disconnect Device Grounding Terminal
9 Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1 and L2 to dis-
connect device line terminals.
10 Over-Current Protection
Select type and size of over-current protec-
tion using Electrical Service Guide (fused
disconnect switch shown).
Close and secure door on disconnect device.
Follow established lockout/tagout proce-
dures to put unit in service.