Miller Dynasty 400 Owner's Manual page 25

Ce and non-ce models
Hide thumbs Also See for Dynasty 400:
Table of Contents

Advertisement

B. Maxstar 400 Models
Welding Amperage Range
3–400 A
Welding range for Stick process
is 5–400 amperes. For TIG, the
amperage range is tungsten di-
ameter dependent. See Section
6-3.
Input
Rated Welding Output
Power
250 A @ 30 Volts,
100% Duty Cycle
Three
300 A @ 32 Volts,
Phase
60% Duty Cycle
400 A @ 36 Volts,
20% Duty Cycle
200 A @ 28 Volts,
100% Duty Cycle
Single
250 A @ 30 Volts,
Phase
60% Duty Cycle
300 A @ 32 Volts,
20% Duty Cycle
This unit is equipped with Auto-Line. Auto-Line is an internal inverter power source circuit that automatically links the power source to
any primary input voltage from 190 to 625 volts, single-or-three-phase, 50 or 60 hertz. It also adjusts for voltage spikes within the entire
range.
C. Dynasty 800 Models
Welding Amperage Range
5–800 A
Welding range for Stick process
is 5–750 amperes. For TIG, the
amperage range is tungsten di-
ameter dependent. See Section
6-3.
Input
Rated Welding Output
Power
500 A @ 40 Volts,
100% Duty Cycle
Three
600 A @ 44 Volts,
Phase
60% Duty Cycle
800 A @ 44 Volts,
20% Duty Cycle
400 A @ 36 Volts,
100% Duty Cycle
Single
Phase
500 A @ 40 Volts,
60% Duty Cycle
This unit is equipped with Auto-Line. Auto-Line is an internal inverter power source circuit that automatically links the power source to
any primary input voltage from 190 to 625 volts, single-or-three-phase, 50 or 60 hertz. It also adjusts for voltage spikes within the entire
range.
Complete Parts List is available at www.MillerWelds.com
Max. Open Circuit Voltage (U
75 V
Normal open-circuit voltage is
present while in Stick with normal
open-circuit voltage selected.
Amperes Input at Rated Load Output 50/60 Hz
208 V
230 V
26
23
33
30
50
45
37
33
48
43
62
55
Max. Open Circuit Voltage (U
75 V
Normal open-circuit voltage is
present while in Stick with normal
open-circuit voltage selected.
Amperes Input at Rated Load Output 50/60 Hz
208 V
230 V
73
66
96
86
123
118
98
88
136
122
)
Low Open-Circuit Voltage (U
0
8–15 V
Low open-circuit voltage is
present while in TIG Lift-Arc, or
while in Stick with low open-cir-
cuit voltage selected.
380 V
400 V
460 V
14
13
12
18
17
15
27
25
22
18
18
24
20
30
28
)
Low Open-Circuit Voltage (U
0
8–15 V
Low open-circuit voltage is
present while in TIG Lift-Arc, or
while in Stick with low open-cir-
cuit voltage selected.
380 V
400 V
460 V
39
37
32
51
48
42
69
65
57
48
41
66
56
Rated Peak Striking Voltage
)
0
(U
)
p
14 kV
Arc starting device is designed
for manual guided operations.
575 V
kVA
9
9.4
12
12.0
11.6
17
18.1
17.3
12
7.4
16
10.0
20
12.8
11.8
Rated Peak Striking Voltage
)
0
(U
)
p
14 kV
Arc starting device is designed
for manual guided operations.
575 V
kVA
25
26.3
25.2
33
34.7
33.2
45
46.9
45.0
32
20.2
18.6
44
28.0
25.8