Note:
dimensions and clearances, and respect their alignment, perpendicularity and flatness.
A dimensional drawing is enclosed with this manual for the help.
Once the VMS has been positioned and secured to its support, the electrical and data connections must be
made in accordance with the diagrams enclosed with this manual (see Enclosure n. 2).
Caution: the power and data connections must be done by a qualified electrician.
Once the installation is completed, clean off any dust, grease or other material that is hampering the good
view of the LED matrix of VMS. Use chemically non-aggressive cleaning materials, taking extra care to avoid
damaging the front of the panel (see para. 6.1 "Interna").
5
.
3
A
c
t
i
v
a
t
i
o
n
a
n
5
.
3
A
c
t
i
v
a
t
i
o
n
a
n
Next to the installation and completion of the electrical & data hookup, the VMS must be activated by
switching it on from the electric control board.
On giving the power, wait for a few seconds as CPU takes some time to reset all its functions. Once the CPU
restores its functions, the operation of VMS is highlighted with the display of a point (or a group of pixels)
at the right side bottom of the matrix.
The
VMS
is configured with a series of operating parameters, which determine its operation in normal
conditions. These parameters are as follows:
Forced Brightness level: The VMS maintains the brightness of the LEDs at a fixed value;
Automatic Brightness: In this mode, the VMS adjusts its brightness autonomously as per the
ambient light;
Time-out: the VMS turns off autonomously if the communication with the local central control
unit or with the Host is lost for a time greater than the predetermined value.
From the Host, it is possible at any time, to send the messages to be displayed on this active VMS and set
other parameters.
Note: in case, after the activation of the data connections, if display shows two points
at the right bottom of the matrix, then please check if the data cable is connected
properly and the server is communicating successfully with panel.
On launching a message, if the panel malfunctions then please refer to the chapter 7 "DIAGNOSTIC ".
Aesys S.p.A. Via Pastrengo 7c - 24068 Seriate - BG - Italy • T. +39 035 29240 • F. +39 035 680030 • www.aesys.com -
when positioning the
d
c
o
m
m
i
s
s
i
o
n
i
n
g
d
c
o
m
m
i
s
s
i
o
n
i
n
g
User and Maintenance Manual [ENG] - rel.00 (26/03/2018)
VMS
on its support, it is essential to consider its
Registered office
Display Series Minerva Monochromatic
: Via Artigiani 41 - 24060 Brusaporto - BG – Italy
Pag.33 di 45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents