Instructions for the installer

12.7 Gas regulations

If the cooking appliance is set up for a different type of gas than that available, its injectors must
be replaced, the minimum flow regulated. In order to replace the injectors in the cooking hob, it is
necessary to carry out the following operations:
remove the pan supports;
remove the burners and burner caps (Fig. A);
take out the injector (Fig. B) and replace it with one
suitable for the new type of gas (see "G
");
INJECTORS TABLE
replace the gas label (on the rear of the appliance) with
the new one provided with the injectors kit;
refit all parts by following the disassembly instructions in
reverse order and taking care to position the burner cap
correctly on the burner.
12.7.1 Minimum flow of valved cooking hob taps
Switch on the burner and turn the control knob
towards the minimum flow position ;
remove the knob;
using a screwdriver, adjust the internal screw Z
until the correct low flame is obtained;
refit the knob.
12.7.2 Minimum flow of non-valved cooking hob taps
Switch on the burner and turn the control knob
towards the minimum flow position ;
remove the knob;
insert a small screwdriver into the rod of the tap
and adjust the internal screw Z until the correct
low flame is obtained;
refit the knob.
Unscrew the adjustment screw Z to increase the flow, or tighten it to reduce the flow.
The adjustment is correct when the low flame measures approximately 3 or 4 mm.
When changing quickly from maximum to minimum flow and vice versa make sure that the
flame does not go out.
TYPE OF GAS
mBar
NATURAL GAS
20
LPG
30
BUTANE
28
PROPANE
37

12.8 Connecting to LPG

Use a pressure regulator and connect to the cylinder in compliance with the guidelines set out in
standards regulations in force.
Note: L.P.G. cookers MUST NOT be installed below ground level i.e. in a basement or aboard any
boat, yacht or other vessel.
GENERAL INJECTORS TABLE
BURNERS
NOZZLE NO.
POSITION TYPE
115
RAPID
97
SEMI RAPID
72
AUXILIARY
128
TRIPLE-RING
94
FISH KETTLE
85
RAPID
65
SEMI RAPID
50
AUXILIARY
93
TRIPLE-RING
68
FISH KETTLE
ENERAL
POWER Watt
MAX.
MIN.
3000
750
1750
480
1000
330
3300
1300
1900
750
3000
750
1750
480
1000
330
3300
1300
1900
750
CONSUMPTION
MAX.
286 l/h
167 l/h
95 l/h
314 l/h
181 l/h
219 g/h
128 g/h
73 g/h
241 g/h
138 g/h

Hide quick links: