Valor H6 1400M Installation Manual page 3

Table of Contents

Advertisement

Available languages

Available languages

Install Fan Into Fireplace
The V-module, power cord and junction box should
already be installed in the firebox as part of the
standard accent lighting supplied with the fireplace. If
not, see the fireplace's installation manual for details on
how to install them.
The V-module will also control the fan. First ensure
power is disconnected from the V-module by unplugging
it from the junction box.
1. Install the fan into the fireplace.
a. Slide the fan inside the fireplace case and push
it as far back as possible so that the threaded
studs at the bottom of the fireplace fit tight
against the end of the slots in the fan mounting
plate.
b. Secure the plate with two nuts provided.
2. Apply provided self-adhesive wiring diagram label
to the fan mounting plate between its fixing studs.
3. Plug the fan relay cable into the "FAN" terminal of
the V-module.
Front of
fireplace
Fan control
module
(v-module)
Control
module
wire to
receiver
View looking left from inside fi rebox (burner
module plate removed). Fan control module
(v-module), power cord and fan control module
wire provided with the fi replace.
Power cord around
back of firebox post
Plug fan relay cable
to control module
Fan
mounting
plate
4. If necessary, thread the power cord around the back
of the firebox post as indicated.
5. Plug the power cable into the receptacle—only after
the other connections mentioned earlier are
complete! An green LED light indicates the
V-module is powered..
6. Test the fan operation before reinstalling the
burner. See "Test Fan Operation" on page 4 .
7. Use the self-adhesive wire clamp provided to secure
the cable between the fan and the control module
to the base of the fireplace.
3