Data not reporting to
www.wunderground.
com or
www.weathercloud.n
et
17. Specifications
17.1 Measurement Specifications
The following table provides specifications for the measured parameters.
Measurement
Indoor
Temperature
Outdoor
Temperature
Indoor Humidity
Outdoor Humidity
Rain
Wind Direction
Wind Speed
Barometric
Pressure:
1. Confirm your password or key is correct. It is
the password you registered on
Wunderground.com. Your Wunderground.com
password cannot begin with a non-alphanumeric
character (a limitation of Wundeground.com, not
the station). Example, $worknet is not a valid
password, but worknet$ is valid.
2. Confirm your station ID is correct.
3. Make sure the date and time is correct on the
console. If incorrect, you may be reporting old
data, not real time data.
4. Make sure your time zone is set properly. If
incorrect, you may be reporting old data, not real
time data.
5. Check your router firewall settings. The console
sends data via Port 80.
Range
32 to 140 °F
± 1 °F
-40 to 140 °F
± 1 °F
10 to 99 %
± 5% (only guaranteed
between 20 to 90%)
10 to 99%
± 5% (only guaranteed
between 20 to 90%)
0 to 396in
<0.6in: ±0.04in,
0.6in to 396in: ±7%
0 - 360 º
± 10º (8 point compass) ± 1º (8 point compass)
0 to 112mph
4.5 mph ~22.4mph:
±0.67mph, 22.4mph
~112mph: ±10%
(whichever is greater)
8.85 to 32.50
± 0.08 inHg
inHg
Accuracy
48
Resolution
0.1 °F
0.1 °F
1 %
1 %
<39.4in (0.012in)
>39.4in (0.04in)
0.1mph
0.01 inHg
Need help?
Do you have a question about the WF-100C Lite and is the answer not in the manual?
Questions and answers