Download Print this page

Midland 70-066 Manual page 63

Conversion to 6 meters
Hide thumbs Also See for 70-066:

Advertisement

should have the same size diameter of the coil retracted from L515 – 5mm]. Each piece of wire should
wind for 6.5 turns [with long ends.]
Solder in five of new wound coils into L515, L516, L517, L518 and L519.
Transmitter PA Modifications to 6 Meters:
Remove L501 and keep; replace with original L114 from the synthesizer board. [4.5 Turns]
]
Remove L503 and keep; replace with original L501. [3.5 Turns
Remove L507 then replace with original L503. [do not keep coil L507 just removed] [2.5 Turns]
Remove L519. Cut back to 2.5 turns and keep coil to replace coil L513.
Remove L513 and keep; replace with old cut back 2.5 turns of coil L519. [2.5 Turns]
Remove original L512; replace with original L513. [1.5 Turns]
Midland 70-066 low Band Conversion to 6 Meters: Transmitter PA Part 4 Ver 2.2 21Nov09 Page 4