The Synthesizer Board.
Remove the synthesizer board from the transceiver assembly.
Midland 70-066 Sync Board Top View below:
TX buffer, remove L114 and keep for use on the PA board; replace with 7.5 turns of 0.63mm wire, same
diameter former. [Use a 5mm drill bit to wind the new coil on.]
Midland 70-066 low Band Conversion to 6 Meters: Synthesizer Part 2