LPG Tank, Fill

WARNING
Read and follow all the refueling precautions and
instructions under Liquefied Petroleum Gas (LPG).
Removable LPG tanks must be removed from the fork lift
before filling.
NOTE: The following instructions are general procedures.
There is a variation in equipment for filling LPG tanks. The
local authorities that have jurisdiction have specific rules and
regulations for filling LPG tanks. Make sure these rules and
regulations are available and understood.
1. Check the gauge on tank to make sure it needs filling.
During the fill operation, the LPG tank must be in a position
168
Legend for Figure 37
B.
(EZ TANK BRACKET)
7.
STOP PIN
8.
BRACKET HANDLE
9.
BRACKET PIVOT
10.
GAS SPRING (EZ TANK BRACKET)
11.
BRACKET RELEASE PIN
so that the liquid level indicator will always be in the vapor
space above the liquid level.
2. Open the liquid outlet valve and bypass return valve on the
storage tank.
3. Start the pump.
4. Connect the supply hose to the quick disconnect fitting on
the LPG tank (see Figure 37). If the LPG tank has an auxiliary
fill fitting, connect the supply hose to this fitting. Make sure
the correct adapter is used to connect the supply hose to the
auxiliary fill fitting.
5. Open the vent valve on the liquid level indicator.
6. Open the fuel valve on the LPG tank.
7. Open the valve on the end of the supply hose.