If the ceiling light does not light up, switch off the mains voltage immediately (take
out the fuse or switch off the circuit breaker, and switch off the earth fault circuit
interrupter).
• Thereafter, check the connections of the ceiling lamp.
• Replace the round light cover removed at the beginning onto the mounting plate and lock it by
turning it clockwise slightly to the right (see fig. 10). At that, the three grooves on the outside
circumference of the light cover must engage with three cap nuts on the inner circumference
of the mounting plate.

Operation

• Once the mounting work is complete, the motion detector operating on the microwave
principle can be configured.
The functioning of the motion detector is tested by moving under the mounted ceiling
light:
• The entire area must be cleared up and secured to eliminate any tripping or injury hazards
before the functional test! In case of insufficient lighting of the area, adequate lighting must
be ensured by other light sources.
• Once the power supply of the ceiling light is switched on, the motion detector switches to the
warm-up phase lasting from approx. 30 seconds to a maximum of 1 minute.
• It is automatically followed by a transition to the automatic mode. Switch off the ceiling lights
by the light switch and test the trigger function by passing under the motion detector. To do
this, set the LUX luminosity switch to <200 and the TIME switch for power-on time to 10 s.
See configuration table. For this purpose, the light cover must be removed and then replaced
again.
• Once the motion detector in the ceiling light receives a valid triggering signal from within the
detection radius (e.g. caused by the movement of a person), the ceiling light switches on for
the selected power-on time.
The actual detection radius can be determined by slow walking!
Configuration table
1
<200 LUX
0
<60 LUX
0
LUX
<20 LUX
1
<5 LUX
1
5 m
x
3.5 m
x
SENS
2 m
x
1 m
x
10 s
x
1 min
x
TIME
4 min
x
10 min
x
1=ON, 0=OFF, x=ON or OFF
Switch 1 to the left, switch 6 to the right
• After the functional test of the motion detector, set the switches
- LUX
(luminosity)
- TIME
(power-on time)
- SENS (detection radius)
as desired
1
0
2
3
4
5
0
x
x
x
1
x
x
x
0
x
x
x
1
x
x
x
x
0
0
x
x
0
1
x
x
1
0
x
x
1
1
x
x
x
x
0
x
x
x
0
x
x
x
1
x
x
x
1

Care and cleaning

• The product is maintenance-free except for lamp replacement.
• Disconnect the product from the power supply before cleaning.
• Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as
they can cause damage to the housing and malfunctioning.
• Only use a dry, fibre-free cloth to clean the product. Optionally, the dust can be removed with
a clean, soft brush.
Never use a damp cloth or water to clean the ceiling light.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product according to
the relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

Input voltage/current .....................................220 – 240 V/AC, 50 Hz
Lamp (not included) ...................................... Light bulbs: 2 x E27, max. 40 W, or
Suitable installation height ............................2.5 – 4 m
Detection range ............................................ 360° and radius max. 5 m
Detection speed ............................................0.3 – 2 m/s
Power-up time ..............................................4 steps: 10 sec. / 1 min. / 4 min. / 10 min.
Luminosity ....................................................adjustable in 4 steps: <5 / <20 / <60 / <200 LUX
IP class .........................................................IP20
Protection class ............................................I
Operating conditions .....................................-5 to +45 ºC, <90 % RH
Storage conditions ........................................-15 to +55 ºC, <90 % RH
Dimensions (Ø x H) ......................................348 x 117 mm
Weight ..........................................................880 g
6
x
x
x
x
x
x
x
x
0
1
0
1
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2017 by Conrad Electronic SE.
energy-saving lamp: 2 x E27, max. 13 W, or
LED: 2 x E27, max. 10 W
(4 steps: 1 / 2 / 3.5 / 5 m)
*1483920_V2_0317_02_hk_m_en

Advertisement

Table of Contents
loading

Table of Contents