CU 1200i Pro /MC

Supply voltage
Current consumption
Cooling capacity at
Q=1 l/min. + 25 °C (77 °F)
Q = 1l / min. + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
Max. delivery head
Max. delivery rate
Max. pump pressure
Pump
Pump service life
Coolant capacity
Degree of protection
Dimensions l/w/h
Weight (without coolant)
Flow monitoring
(sensor)
Coolant temperature monitoring
Level sensor*
(functionality depends on the options in-
stalled in the device)
Mark of conformity
* Optional
80
CU 1200i Pro /MC
(164 ft. 0.5 in.)
(0.47 gal./min [US])
up to 20,000 hrs
(1.59 gal. [US])
710/300/230 mm
(27.95/11.81/9.06 in.)
Warning at 1 - 0.7 l/min
(0.26 - 0.18 gal./min [US])
Error message below 0.7 l/min
(0.18 gal./min [US])
Warning above 68 °C (154.4 °F)
Error message above 70 °C (158 °F)
Warning or error message
24 V DC
2.1 A
1200 W
800 W
1400 W
1100 W
50 m
1.8 l/min
5 bar
(72.51 psi
Gear pump
6 l
IP 23
12 kg
(26.46 Ib.)
CE, CSA

Hide quick links: