Danger From Escaping Shielding Gas; Safety Measures At The Installation Location And During Transport; Safety Measures In Normal Operation - Fronius CU 800i Operating Instructions Manual

Hide thumbs Also See for CU 800i:
Table of Contents

Advertisement

If the shielding gas cylinder is not connected, leave the valve cap in place on the cylin-
der.
The manufacturer's instructions must be observed as well as applicable national and in-
ternational regulations for shielding gas cylinders and accessories.
Danger from es-
Risk of suffocation from the uncontrolled escape of shielding gas
caping shielding
Shielding gas is colourless and odourless and, in the event of a leak, can displace the
gas
oxygen in the ambient air.
-
-
-
-
Safety measures
A device toppling over could easily kill someone. Place the device on a solid, level sur-
at the installation
face such that it remains stable
location and dur-
-
ing transport
Special regulations apply in rooms at risk of fire or explosion
-
Use internal directives and checks to ensure that the workplace environment is always
clean and clearly laid out.
Only set up and operate the device in accordance with the degree of protection shown
on the rating plate.
When setting up the device, ensure there is an all-round clearance of 0.5 m (1 ft. 7.69
in.) to ensure that cooling air can flow in and out freely.
When transporting the device, observe the relevant national and local guidelines and ac-
cident prevention regulations. This applies especially to guidelines regarding the risks
arising during transport.
Do not lift or transport operational devices. Switch off devices before transport or lifting.
Before transporting the device, allow coolant to drain completely and detach the follow-
ing components:
-
-
-
After transporting the device, the device must be visually inspected for damage before
commissioning. Any damage must be repaired by trained service technicians before
commissioning the device.
Safety measures
Only operate the device when all safety devices are fully functional. If the safety devices
in normal opera-
are not fully functional, there is a risk of
tion
-
-
-
Any safety devices that are not functioning properly must be repaired before switching on
the device.
Ensure an adequate supply of fresh air with a ventilation rate of at least 20 m³/hour.
Observe safety and maintenance instructions on the shielding gas cylinder or the
main gas supply.
Close the shielding gas cylinder valve or main gas supply if no welding is taking
place.
Check the shielding gas cylinder or main gas supply for uncontrolled gas leakage
before every start-up.
The maximum permissible tilt angle is 10°.
Observe relevant national and international regulations.
Wirefeeder
Wirespool
Shielding gas cylinder
injury or death to the operator or a third party
damage to the device and other material assets belonging to the operator
inefficient operation of the device