Technical Data; General; Cu 800I, Cu 800I /460 - Fronius CU 800i Operating Instructions Manual

Hide thumbs Also See for CU 800i:
Table of Contents

Advertisement

Technical data

General

The cooling capacity of a cooling unit depends on
-
-
-
CU 800i,
CU 800i /460 V
Mains voltage
Mains voltage tolerance
Grid frequency
Current consumption
Cooling capacity at
Q=1 l/min. + 25 °C (77 °F)
Q = 1l / min. + 40 °C (104 °F)
Q = max. + 25 °C (77 °F)
Q = max. + 40 °C (104 °F)
Max. delivery head
Max. delivery rate
Max. pump pressure
Pump
Pump service life
Coolant capacity
Degree of protection
Dimensions l/w/h
Weight (without coolant)
Flow monitoring*
(sensor)
Coolant temperature monitoring*
Mark of conformity
* Optional
Ambient temperature
Delivery head
Flow rate Q (l/min) - The flow rate Q depends on the length of the interconnecting
hosepack and the diameter of the hose.
-10% / +10%
(114 ft. 9.95 in.)
(0.92 gal./min [US])
Centrifugal pump
approx. 10,000 hrs
(1.19 gal. [US])
706/260/219 mm
(27.8/10.24/8.62 in.)
Warning at 1 - 0.7 l/min
(0.26 - 0.18 gal./min [US])
Error message below 0.7 l/min
(0.18 gal./min [US])
Warning above 68 °C (154.4 °F)
Error message above 70 °C (158 °F)
CU 800i
400 V AC
50/60 Hz
0.7 A
800 W
500 W
1160 W
730 W
35 m
3.5 l/min
4.2 bar
(60.92 psi)
4.5 l
IP 23
11.2 kg
(24.69 Ib.)
CE
73