Technical Data; Cgeneral Information; Law Requirements Only For Australia; Introduction - Electrolux N7E Installation And Operating Manual

Pasta cooker
Table of Contents

Advertisement

Pmbar
Electrolux Professional SpA Viale Treviso 15 33170 Porde-
none Italy
B.3

Technical data

Gas appliances N9E
Connection ISO 7/1
Nominal heat output
Type of construction
Electric appliances N9E
Power supply voltage
Phases
Frequency
Tank capacity (filling level)
Max Power
Power supply cable section
1.
Minimum recommended.
Gas/Electric appliances N7E
Data
Tank capacity (filling level)
Connection ISO 7/1
Nominal heat output
Type of construction
Power supply voltage
Phases
Frequency
Max Power
Power supply cable section
1.
Minimum recommended.
C
GENERAL INFORMATION
WARNING
Refer to "Warning and Safety
Information".
C.1

Law requirements only for Australia

This appliance shall be installed only by authorised persons
and in accordance with the manufacturer's installation instruc-
tions, local gas fitting regulations, municipal building codes,
electrical wiring regulations, local water supply regulations,
AS5601-gas installation, health authorities and any other
statutory regulations.
C.2

Introduction

Given below is some information regarding the intended use of
this appliance, its testing, and a description of the symbols
used (that identifies the type of warning), the definitions of
terms used in the manual and useful information for the
appliance user.
Data
kW – Max
kW – Min.
Data
V
No.
Hz
L
kW
1
mm
L
kW
V
No.
Hz
kW
1
mm
2
gas pressure
manufacturer
+9PCGD1MF0
400mm
1/2"
16,5
-
A1
+9PCED1MF0
400mm
400
3+N
50/60
40
10
2
2,5
+7PCGD1KF0
+7PCGH2KF0
400mm
800mm
25
25+25
1/2"
1/2"
11,5
23
A1
A1
-
-
-
-
-
-
-
-
-
-
C.3

Intended use and restrictions

This appliance is designed for cooking food. It is intended for
commercial use.
This appliance must not be used by minors and/or adults
with limited physical, sensory or mental abilities or with-
out adequate experience and knowledge regarding its use.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
CAUTION
The machine is not suitable for installation
outdoors and/or in places exposed to
atmospheric agents (rain, direct sunlight,
etc.).
C.4

Testing and inspection

Our appliances have been designed and optimized, with
laboratory testing, in order to obtain high performance and
efficiency.
MODELS
+9PCGH2MF0
800mm
1/2"
33
-
MODELS
+9PCEH2MF0
800mm
400
3+N
50/60
40+40
20
6
MODELS
+7PCED1KF0
+7PCEH2KF0
400mm
800mm
25
25+25
-
-
-
-
-
-
380–400
400
3+N
3+N
50/60
50/60
5,4 – 6
10,8 – 12
1,5
4
+7PCED1KFP
400mm
25
-
-
-
400
3+N
50/60
8,2 – 9
2,5
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

N9e

Table of Contents