Service Test - Teka LP2 140 Service Manual

Hide thumbs Also See for LP2 140:
Table of Contents

Advertisement

The components marked as Opc.(1) and Opc.(2) are only included in some models.

4. Service Test

Once the service test is launched (see how to start it in the specific page for your
model), the following sequence will be executed:
Nº Display (*) Consumption (A)
0
8:88
≈ 0,0
1
05 or
≈ 0,04
(value)
2
04 / temp. ≈ 8,0
3
03
≈ 0,4
≈ 0,05
4
02
≈ 0,05
5
01
≈ 0,2
6
F
≈ 0,0
(*) Models without display will turn on and off the program led sequentially during the
service test.
Service Manual:
MSDW16012
Service Manual
Test Service
Description
Start test
The inlet valve turns on until 3.6 l. are loaded
(3 l. for 45 cm. models).
If the model is equipped with alternative valve,
it will be working in this step. If the model is
equipped with turbidity sensor, the display will
show the value it is measuring.
The washing pump starts working at high
speed and 10 seconds later, the heater
element will turn on until water temperature
reaches 57º C. Then, the test will pause until
the "Program" or "Start/Pause" (depending on
the model) button is pressed.
The washing pump starts working at low
speed. After 8 seconds, the dispenser turns on
for 45 seconds.
Regeneration valve turns on for 30 seconds.
The draining pump turns on for 30 seconds.
Test ends. The dishwasher beeps once and
stays in stand.
- 5 -