Craftsman 919.167551 Owner's Manual page 18

Permanently lubricated air compressor
Table of Contents

Advertisement

Available languages

Available languages

voltage sources, compressed air, or moving parts. Before servicing unit
unplug or disconnect electrical supply to the air compressor, bleed tank of
pressure, and allow the air compressor to cool.
PrOBLeM
Excessive
tank pressure
- safety valve
pops off.
Air leaks at fit-
tings.
Air leaks at or
inside check
valve.
Air leaks in air
tank or at air
tank welds.
Air leaks
between head
and valve plate.
TROUBLESHOOTING
Risk of Unsafe Operation. Unit cycles automatically when
power is on. When servicing, you may be exposed to
CAUSE
Pressure switch does not
shut off motor when
compressor reaches
"cut-out" pressure.
Pressure switch "cut-out"
too high.
Tube fittings are not tight
enough.
Check valve seat damaged.
Defective air tank.
Leaking seal.
CORRECTION
Move Auto/Off lever to the
"Off" position, if the outfit
does not shut off contact a
Trained Service Technician.
Contact a Trained Service
Technician.
Tighten fittings where air can
be heard escaping. Check
fittings with soapy water solu-
tion. Do Not Overtighten.
Replace check valve. Refer to
the To Replace Check Valve
in the Service and Adjustment
section.
Air tank must be replaced. Do
not repair the leak.
Do not drill into, weld or
otherwise modify air tank or
it will weaken. The tank can
rupture or explode.
Contact a Trained Service
Technician.
18- ENG
Risk of
Bursting

Advertisement

Chapters

Table of Contents
loading

Table of Contents