Siemens SIMATIC NET RUGGEDCOM RS920W Installation Manual page 43

Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS920W:
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
61000-4-3
61000-4-4
61000-4-5
61000-4-6
61000-4-8
61000-4-11
61000-4-12
61000-4-16
61000-4-17
34
Test
IEC
Radiated RFI
IEC
Burst (Fast Transient)
IEC
Surge
IEC
Induced (Conducted) RFI
IEC
Magnetic Field
IEC
Voltage Dips and Interrupts
IEC
Damped Oscillatory
IEC
Mains Frequency Voltage
IEC
Ripple on DC Power Supply
Description
Enclosure
Ports
Signal Ports
DC Power
Ports
AC Power
Ports
Earth
Ground Ports
Signal Ports
DC Power
Ports
AC Power
Ports
Signal Ports
DC Power
Ports
AC Power
Ports
Earth
Ground Ports
Enclosure
Ports
AC Power
Ports
Signal Ports
DC Power
Ports
AC Power
Ports
Signal Ports
DC Power
Ports
DC Power
Ports
Test Levels
20 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
± 4 kV Line-to-Ground
± 2 kV
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
10 V
10 V
10 V
10 V
40 A/m Continuous
1000 A/m for 1 s
100% for 5 Periods
100% for 50 Periods
2.5 kV Common
Mode @ 1 MHz
1 kV Differential
Mode @ 1 MHz
2.5 kV Common
Mode @ 1 MHz
1 kV Differential
Mode @ 1 MHz
2.5 kV Common
Mode @ 1 MHz
1 kV Differential
Mode @ 1 MHz
30 V Continuous
300 V for 1 s
30 V Continuous
300 V for 1 s
10%
Installation Manual, 04/2021, C79000-G8976-1033-09
Severity
Levels
x
4
4
4
4
3
4
3
3
3
3
 
 
3
3
3
4
4
3
RUGGEDCOM RS920W

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIMATIC NET RUGGEDCOM RS920W and is the answer not in the manual?

Table of Contents