Summary of Contents for CDA EVPK9

  • Page 1 Manual for Installation, Use and Maintenance Passionate about style Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www.cda.eu...
  • Page 2 Under no circumstances should any external covers be removed for servicing or maintenance except by suitably qualified personnel. Appliance information: Please enter the details on the appliance rating plate below for reference, to assist CDA Customer Care in the event of a fault with your appliance and to register your appliance for guarantee purposes. Appliance Model...
  • Page 3: Using Your Extractor

    Using your Extractor For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking. Control Panel A - Light key B - Decrease speed key C - Display D - Increase speed key E - Timer key...
  • Page 4: Care And Maintenance

    Care and Maintenance IMPORTANT : DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. Cleaning You should use a nonabrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and could erase the control panel markings. You can clean your extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth.
  • Page 5: Changing The Light

    Changing the Light DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT. ALLOW IT TO COOL BEFORE REMOVING IT. Using a flat blade screwdriver, carefully prise off the lamp cover as shown in figure 5.
  • Page 6: Mains Electricity Connection

    Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE. We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E.
  • Page 7: Electrical Information

    Electrical Information Mains electrical voltage: 230 – 240Vac, 50Hz Total rated power consumption: 290W Troubleshooting If your extractor is not working: Check that the mains supply has not been switched off. Check that the fuse in the spur has not blown.
  • Page 8: Mounting Your Extractor

    Mounting your Extractor IMPORTANT: The extractor is intended to be mounted directly to the ceiling using fixings appropriate for the ceiling. Ensure that there is adequate ceiling strength and supports at the fixing points; if in doubt, consult a joiner or electrician. When the extractor is to be installed above an electric hob, the minimum distance between the hob and extractor must exceed 600mm (650mm is recommended).
  • Page 9: Installation

    Installation Your extractor can be used to filter and recycle the air within your kitchen (A), or to extract the air outside (B). When extracting air to the outside, the unit can be vented as shown in the diagram below. To mount your extractor to the ceiling 1.
  • Page 10 Installation 4. Insert 3 screws into the main fixings, leaving approximately 3mm protruding, as shown in Fig 7 5. Fit the upper support section (B) into position on the 3 screws and rotate it into position, as shown in Fig 7. 6.
  • Page 11 Installation 9. Assemble the ventilation duct(H), as shown in the diagrams below dependant on whether you are extracting air to the outside (Fig 10) or re-circulating (Fig 11), in which case you will need to use the supplied T-piece (M). Ensure that the duct adapter (F) is securely connected to the duct pipe or T-piece in order to minimise noise.
  • Page 12 Installation 11. Mount the upper chimney section onto the frame section and secure in position using the 2 screws (A) as in Fig 13. 12. Carefully slide the lower section over the upper section and tape it in position (L) near the shortest position. 13.
  • Page 16 Passionate about style Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www.cda.eu...