3. Charging

3.1
IMPORTANT: READ THE CHARGER HANDBOOK BEFORE ATTEMPTING TO
CHARGE THE BATTERY.
3.2
NOTE: The battery is put into 'ship mode' prior to transit.
It can be activated by connecting it to a charger that is
powered-up, or by linking it to a battery that is already active.
3.3
Mini PAGlink batteries can be charged individually or linked, regardless
of their capacity or state of charge. They can be partially charged and
discharged without suffering any damaging effects. They can also be
charged when linked to PAGlink Gold Mount batteries Models 9306
(PL94) and 9313 (PL150).
3.4
Up to 10 Mini PAGlink batteries can be linked for charging on each
position. The least-charged batteries are given priority until all the
batteries are within 20% state-of-charge, when they will all be fully-
charged simultaneously. If you connect only one battery to the
charger it will receive all the current, and charge in the quickest
possible time. The following PAGlink chargers can be used:
9707A PAGlink PL16 Charger
9711A PAGlink PL16+ Charger
9713
PAGlink Micro Charger
Some Anton Bauer chargers will charge linked batteries to 100% if
they are within 40% state-of-charge of each other to begin with. You
can charge the most-discharged batteries individually until they are
within 40% of the others and then link them up for a 100% charge.
2-positions, 10 batteries on each
4-positions, 10 batteries on each
1-position, 10 batteries in total
3.5
Charge Times: From fully-discharged to fully-charged:
Capacity
50Wh
100Wh
200Wh
300Wh
400Wh
600Wh
800Wh
1600Wh
Each charging position of the PL16 charger receives the same current
simultaneously and it is better to spread batteries evenly across both
channels to achieve the fastest charge time. Batteries that have a
similar state-of-charge should also be stacked together for the most
efficient use of power.
3.6
Mini PAGlink batteries display their individual status during
charging on their built-in display.
3.7
The batteries incorporate a temperature sensor which will inhibit
charging if their temperature is below 0°C. See Specification for the
charging temperature range.
PL16
Micro Charger
01:15
02:00
01:30
04:00
03:00
08:00
04:45
12:00
06:00
16:00
09:00
24:00
12:00
-
24:00
-