Error Code Table - Sharp UX-177 Service Manual

Table of Contents

Advertisement

UX-177H

[4] Error code table

G3 Transmission
Code
Final received signal
0
Incomplete signal frame
1
NSF, DIS
2
CFR
3
FTT
4
MCF
5
PIP or PIN
6
RTN or RTP
7
No signal or DCN
G3 Reception
Code
Final received signal
0
Imcomplete signal frame
1
NSS, DCS
2
NSC, DTC
3
EOP
4
EOM
5
MPS
6
PR1-Q
7
No signal or DCN
Cannot recognize bit stream after flag
Cannot recognize DCS signal
Cannot recognize NSS signal
Disconnects line during reception
Disconnects line by fallback
Disconnects line during reception of multi-page
Cannot recognize NSS, DCS signal in the case of mode change
No response in receiver side to picture signal after no response in transmitter side to receive
TALK mode request
Cannot recognize NSS, DCS signal after transmitting RTN or RTP signal.
No response in receiver side or DCN signal received*
Cannot recognize bit stream after flag
Cannot recognize CFR or FTT signal
Disconnects line during transmission
Cannot recognize NSS signal
Cannot recognize MCF, PIP, PIN, RTN, RTP signal
Cannot recognize MCF, PIP, PIN, RTN, RTP signal in the case of mode change
Cannot recognize MCF, PIP, PIN, RTN, RTP signal in the case of multi-page
Cannot recognize PIP, PIN signal in the case of TALK request
No response in transmitter (cannot recognize DIS signal) or DCN signal received*
2 – 16
Error Condition (Receiver side)
Error Condition (Transmitter side)