Soft switch function description
SW-A1 No. 1 Protection from echo
Used to protect from echo in reception.
SW-A1 No. 2 Forced 4800 bps reception
When line conditions warrant that receptions take place at 4800 bps
repeatedly.
It may improve the success of receptions by setting at 4800 bps.
This improve the receiving document quality and reduces handshake
time due to fallback during training.
SW-A1 No. 3 Footer print
When set to "1", the date of reception, the sender machine No., and
the page No. are automatically recorded at the end of reception.
SW-A1 No. 4 Maximum copy, transmit, receive page length
Used to set the maximum page length.
To avoid possible paper jam, the page length is normally limited to 1
meter for copy or transmit, and 1.5 meters for receive.
It is possible to set it to "No limit" to transmit a long document, such
as a computer print form, etc. (In this case, the receiver must also be
set to no limit.)
SW-A1 No. 5 CSI transmission
(CSI TRANSMISSION) is a switch to set whether the machine sends
or does not send the signal (CSI signal) informing its own telephone
No. to the remote fax, machine when information is received. When
"nonsending" is set, the telephone No. is not output on the remote
transmitting machine if the remote transmitting machine has the func-
tion to display or print the telephone No. of receiving machine, using
this CSI signal.
SW-A1 No. 6 DIS receive acknowledgment during G3 transmis-
sion
Used to make a choice of whether reception of DIS (NSF) is acknowl-
edged after receiving two DISs (NSFs) or receiving one DIS (two
NSFs).
It may be useful for overseas communication to avoid an echo sup-
pression problem, if set to 1.
SW-A1 No. 7 Non-modulated carrier detection for V29 modem
Though transmission of a non-modulated carrier is not required for
transmission by the V29 modem according to the CCITT Recommen-
dation, it may be permitted to a send non-modulated carrier before
the image signal to avoid and echo suppression problem.
It may be useful for overseas communication to avoid an echo sup-
pression problem, if set to 1.
SW-A1 No. 8 EOL (End Of Line) detect timer
Used to make a choice of whether to use the 25-second or 13-second
timer for detection of EOL.
This is effective to override communication failures with some facsim-
ile models that have longer EOL detection.
SW-A2 No. 1 ~ No. 4 Modem speed
Used to set determine the initial modem speed. The default is 9600
bps.
It may be necessary to program it to a slower speed when frequent
line fallback is encountered, in order to save the time required for
fallback procedure.
SW-A2 No. 5 Sender's information transmit
(SENDER'S INFORMATION TRANSMISSION) is a switch to set the
function to print the content of HEADER PRINT described in the
passcode list at the front end of receiver's original when original is
sent to the remote machine.
If this switch is set to "NO", the HEADER PRINT is not output at the
receiving machine.
SW-A2 No. 6 H2 mode (SHARP special mode)
Used to determine reception of H2 mode (15 sec transmission mode).
When set to OFF, H2 mode reception is inhibited even though the
transmitting machine has H2 mode function.
SW-A2 No. 7 Communication error treatment (reception) in RTN
sending
Used to determine communication error treatment when RTN is sent
by occurrence of a received image error in G3 reception. When it is
set to "1", communication error is judged as no error.
SW-A2 No. 8 CNG transmission
When set to "0", this model allows CNG transmission by pressing the
Start key in the key pad dialing mode. When set to "1", CNG trans-
mission in the key pad dialing mode cannot be performed. In either
case, CNG transmission can be performed in the auto dial mode.
SW-A3 No. 1, No. 2 CED tone-signal interval
For international communication, the 2100Hz CED tone may act as
an echo suppression switch, causing a communication problem.
Though SW-A3 No. 1 and No. 2 are normally set to 0, it should be
changed this timer between the CED tone signal to eliminate the
communication problem caused by echo.
SW-A3 No. 3 ~ No. 8 Reserved
Set to "0".
SW-A4 No. 1 ~ No. 5 Signal transmission level
Used to control the signal transmission level in the range of-0dB to
-31dB.
The factory setting is at -8dB (MODEM output).
SW-A4 No. 6 Protocol monitor (Error print)
If set to "1", protocol is printed at communication error.
SW-A4 No. 7 Protocol monitor
Normally set to "0". If set to "1", communication can be checked, in
case of troubles, without using a G3 tester or other tools.
When communication FSK data transmission or reception is made,
the data is taken into the buffer. When communication is finished, the
data analyzed and printed out. When data is received with the line
monitor (SW4-No. 8) set to "1" the reception level is also printed out.
SW-A4 No. 8 Line monitor
Normally set to "0". If set to "1", the transmission speed and the
reception level are displayed on the LCD. Used for line tests.
SW-A5 No. 1, No. 2 Digital equalization setting (Reception)
Line equalization when reception is to be set according to the line
characteristics.
Setting should be made according to distance between the telephone
and the telephone company central switching station.
SW-A5 No. 3 ~ No. 6 Reserved
Set to "0".
SW-A5 No. 7 Error criterion
Used to select error criterion for sending back RTN when receiving
image data.
SW-A5 No. 8 Anti junk fax check
When use the Anti junk fax function, set to "1".
SW-A6 No. 1 Auto gain control (MODEM)
When this mode is enabled, If the reception signal level is under
31dBm. The modem itself controls the signal gain automatically.
2 – 11
TX
RX
T
UX-177H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ux-177h

Table of Contents