Please carefully read this manual before using the Pump, in particular follow the safety information. UDOR declines any responsability for damage resulting from not observing the instructions indicated in this manual. Store in a suitable place to keep...
Expenses for labour and transport are to the charge of the buyer. The product shall only be returned to UDOR following authorization from the latter, free of charge to the warehouse of UDOR and complete with every single original component, without any sign of tampering.
3. INTENDED USE UDOR Plunger Pumps are designed to be used in machines or systems for transferring pressurized water, such as the following for example: High Pressure Cleaning, High Pressure Descaling, Chemical Process. The temperature of the workplace shall be between: Min. 0°C (32°F) - Max.40°C (104°F) The Pump cannot be used submerged under any type of liquid.
The UDOR pumps of the VY series must be supplied at an inlet pressure between 2 and 6 bar (0.2 MPa and 0.6 MPa - 29 and 87 PSI). If a Booster Pump is used, which is to be started before the UDOR pump, it shall have a minimum flow rate at least double the flow rate of the model of pump of the VY series used;...
7. CONTROLS ON SYSTEM 7.1 PRESSURE REGULATOR A pressure regulator valve must be installed to avoid the pressure exceeding the maximum limit indicated on the Label of the Pump. Use of the Pump, even for a short period, with a pressure higher than such limit would damage the Pump itself.
PSI). - Let the pump run in these conditions for a couple of minutes, checking that the pipes, connections and components of the system are in perfect working conditions and making sure there are no leaks or drips of water. - At the end of this settling-in and inspection cycle, the system can be taken to the required pressure, without ever exceeding the maximum pressure written on the nameplate of the pump itself.
Use OIL type CLP 220 or an alternative Gear Oil type SAE 85W-90. Here are some recommended types of oil: BRAND TYPE AGIP F.1 Supermotoroil 15W-40 Vanellus C 15W-40 CASTROL GTX 15W-40 ESSO Uniflo 15W-40 MOBIL Super M 15W-40 SHELL Rimula R4 15W-40 / Helix Super 15W40 TOTAL Rubia 15W-40 / Quartz 5000 15W-40...
Page 10
Abrasive material in the fluid being Install proper filter on Pump inlet Frequent or premature Pumped. plumbing. failure of the packing. Use clean water or contact UDOR Corrosive additeves in the fluid being Technical Service Department for more Pumped. informations. Running Pump dry.
MAINTENANCE LOG DATE OF DATE OF PUMP MODEL PUMP CODE SERIAL NUMBER INSTALLATION PURCHASE OPERAT. DATE NOTES MAINTENANCE WORKS HOURS OIL CHANGE POWER END OIL SEAL AND GASKET (KIT 651) FLUID END O-RING (KIT 653) HIGH & LOW PRESSURE WATER SEALS (KIT 667 OR KIT 652 OR KIT 657) BRASS RINGS (KIT 668 OR KIT 655 OR KIT 656)
They also comply with the following Standard: UNI EN 809. It is additionally specified that: • The Relevant Technical Documentation is kept at UDOR S.p.A. premises in: Via A. Corradini, 2 – 42048 Rubiera (Reggio Emilia) – Italy, in the person of its legal representative.
Page 24
It is forbidden to reproduce or translate any part of this manual without written VY - 10/20 authorization from the owner. UDOR USA reserves the right to add modifications to the products, information and Rev. 1.6 illustrations herein without notice.