UDOR DELTA 140 Use And Maintenance Manual

UDOR DELTA 140 Use And Maintenance Manual

Diaphragm pumps

Advertisement

USE AND MAINTENANCE MANUAL FOR DIAPHRAGM PUMPS
assembly instructions

Advertisement

Table of Contents
loading

Summary of Contents for UDOR DELTA 140

  • Page 1 USE AND MAINTENANCE MANUAL FOR DIAPHRAGM PUMPS assembly instructions...
  • Page 3 COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNV GL ISO 9001  Please carefully read this manual before using the Pump, in particular follow the  safety information. Store in a suitable place to keep it unalterate.
  • Page 4 INDEX PAGE GENERAL INFORMATION 1.1 SAFETY SYMBOLS 1.2 PUMP IDENTIFICATION 1.3 WARRANTY INTRODUCTION INTENDED USE OPERATIONAL RESTRICTIONS GENERAL WARNINGS BEFORE START UP 6.1 LIQUIDS TO BE PUMPED 6.2 INLET AND OUTLET OF THE PUMP 6.3 INLET CONDITIONS (SUCTION) 6.4 OUTLET CONDITIONS 6.5 SPEED AND ROTATION DIRECTION CONTROLS ON SYSTEM 7.1 UNLOADER VALVE...
  • Page 5: General Information

    UDOR, are considered to be defective from the date of shipment. Expenses for labour and transport are to the charge of the buyer. The product shall only be returned to UDOR following authorisation from the latter, free of charge to the warehouse of UDOR and complete with every single original component, without any sign of tampering.
  • Page 6: Intended Use

    INTENDED USE The Diaphragm Pumps of UDOR are designed for use in machines or systems that transfer water or pesticides or herbicides, under pressure, such as the following for example: Sprayers, Mist Sprayers, Herbicide Spray Booms, Gardening, Civil and Industrial Washing Systems, Drain and Pipe Cleaning, Fire-fighting, Antifreeze Systems.
  • Page 7: Controls On System

    The rotation speed of the shaft of the Pump must never exceed the RPM written on the Label of the actual Pump. The minimum RPM admitted is: maximum RPM x 0.6. The rotation direction of the shaft of UDOR Pumps may be clockwise or anticlockwise CONTROLS ON SYSTEM UNLOADER VALVE A pressure regulator valve must be installed to avoid the pressure exceeding the maximum limit indicated on the Label of the Pump.
  • Page 8: Pressure Gauge

      Accumulator Pressure UDOR normally inflates the Pumps pulsation dampener at a pressure of 5 bar (72 PSI) approx PRESSURE GAUGE Install a gauge as near as possible to the outlet of the Pump because the maximum pressure written on the Pump’s Label refers to the pressure detected in that point and not on the nozzle or on other...
  • Page 9: Precautions Against Freezing

    SWITCHING OFF AND STORAGE After use or if the Pump is to be put away in storage, wash it internally. You can do this by running the Pump for several minutes with clean water, then disconnect the supply line and leave the Pump to run for approximately 15 seconds so that all the water inside the pump is drained.
  • Page 10 (C). Reinstall cover (D) and tighten the screws (A) with the proper torque (see page 19). Recharge dampener with air according to UDOR specifications at page 13. 8. REFILL PUMP CRANKCASE: Re-mount the oil drain plug (T). Fill Pump with SAE 15W-40 OIL to recommended mark on the oil reservoir (H) or on the sight glass (S).
  • Page 11: Troubleshooting

    During maintenance, do not throw residues outdoors but observe current standards. If the Pump is to be scrapped: 1. Separate the various parts depending on their type (i.e. plastic, harmful fluids, metal etc.). 2. Use public or private waste disposal systems envisaged by local law to dispose of waste.
  • Page 12: Oil And Weight

    KAPPA 65 DELTA 75 2.29 0.31 1,04 1,16 DELTA 100 2.25 0.30 1,02 1,14 DELTA 125 4.01 0.54 1,82 2,03 DELTA 140 3.20 0.42 1.45 1.62 DELTA 170 3.96 0.52 1.80 2.00 OMEGA 135 3.20 0.42 1.45 1.62 OMEGA 139 3.20...
  • Page 13: Torque Specifications

    12. TORQUE SPECIFICATIONS...
  • Page 14 - - - - - - - - - - - - DELTA 125 - - - - - - - - - - - - DELTA 140 - - - - - - DELTA 170 - - - - - - OMEGA 135...
  • Page 15 They also comply with the following Standard: UNI EN 809. It is additionally specified that: • The Relevant Technical Documentation is kept at UDOR S.p.A. premises in: Via A. Corradini, 2 – 42048 Rubiera (Reggio Emilia) – Italy, in the person of its legal representative.
  • Page 16 UDOR S.p.A. 080594 Via A. Corradini, 2 - 42048 Rubiera (Reggio Emilia) - ITALY 06/20 Tel. (+39) 0522 628249 - Fax (+39) 0522 628953 Rev. 3.1 info@udor.it - www.udor.it...