QUICK COUPLERS CLOSING/OPENING:
Opening (connect to
the vehicle):
clockwise
Closing (detach from
the vehicle):
counter clockwise
MAINTENANCE/GENERAL CLEANING: The equipment
has to be serviced at the intervals indicated by the
has to be serviced at the intervals indicated by the
equipment itself.
The service station maintenance has to be performed
according to the procedures described in this manual and
according to the procedures described in this manual and
to the current safety regulations.
Use only MAHLE original parts.
When the equipment requires the drier filter and the vacuum
When the equipment requires the drier filter and the vacuum
pump oil to be changed, you have to be careful in the
pump oil to be changed, you have to be careful in the
replacement.
A/C service station maintenance can be carried out
A/C service station maintenance can be carried out
exclusively by a trained operator or by a service man of a
exclusively by a trained operator or by a service man of a
MAHLE certified seller.
Do not use chemical agents for the service station cleaning
Do not use chemical agents for the service station cleaning
as they could attack the material or the surface.
STOP FOR LONG PERIOD: Store the equipment in a safe
place, disconnected from the mains, away from excessive
place, disconnected from the mains, away from excessive
temperatures, humidity and the risk of damaging impact.
temperatures, humidity and the risk of damaging impact.
Contact the Technical Service to run a safety shutdown of
Contact the Technical Service to run a safety shutdown of
the equipment, and if scrapping the unit, to drain and
scrapping the unit, to drain and
recycle the R134a or R1234yf refrigerant as required by
recycle the R134a or R1234yf refrigerant as required by
local legislation.
To resume operation, repeat the installation (there is no
To resume operation, repeat the installation (there is no
need to register the unit anew on the website) and run the
need to register the unit anew on the website) and run the
commissioning trials and regular operational checks as
required by local legislation.
2.2
Important information on service
Important information on service
equipment safety
When using the equipment, the following operations are not
When using the equipment, the following operations are not
allowed as they might cause, under certain circumstances,
allowed as they might cause, under certain circumstances,
danger for persons and cause permanent damage to the
equipment itself.
- Do not remove or make unreadable labels,
Do not remove or make unreadable labels,
signs and/or dangers signs placed on the
signs and/or dangers signs placed on the
equipment and in the area nearby.
- Do not disable the unit's safety equipment.
Do not disable the unit's safety equipment.
- The electrical system to which the service
The electrical system to which the service
equipment is connected must be configured as
equipment is connected must be configured as
provided by local legislation.
© MAHLE
The equipment
has to be performed
Store the equipment in a safe
r operational checks as
permanent damage to the
- Only operators or qualified staff instructed or
Only operators or qualified staff instructed or
certified for the equipment
open the equipment. The equipment
parts which can cause electrocution: shut off
parts which can cause electrocution: shut off
power
power
to
to
servicing/repairing it.
2.3

Safety devices

The A/C service station is equipped with the following safety
is equipped with the following safety
devices:
SAFETY PRESSURE SWITCH: It stops the compressor
SAFETY PRESSURE SWITCH
in case of excessive pressure.
SAFETY VALVE: The safety valve opens when the
pressure inside the system reaches a level higher than the
pressure inside the system reaches a level higher than the
fixed limits.
MAIN
SWITCH:
interrupting the power supply. It is advisable to pull the
interrupting the power supply. It is advisable to pull the
power cord plug out of the mains socket in any case
power cord plug out of the mains socket in any case
before starting maintenance work.
before starting maintenance work.
ANY TAMPERING WITH THE ABOVE-MENTIONED
ANY TAMPERING WITH THE ABOVE
SAFETY DEVICES IS PROHIBITED.
SAFETY DEVICES IS PROHIBITED.
Failure to observe any of the above safety instructions voids the
Failure to observe any of the above safety instructions voids the
equipment's warranty.

3 Layout of the manual

Layout of the manual
3.1

Use of the manual

This manual is an integral part of the equipment and
This manual is an integral part of the equipment and
must be kept in the equipment's immediate vicinity by
must be kept in the equipment's immediate vicinity by
the purchaser
This manual shall accompany the equipment in case this is
This manual shall accompany the equipment in case this is
passed on to a new user.
The content of this manual has been drawn up in
The content of this manual has been drawn up in
compliance with the guide lines of the UNI standard
compliance with the guide lines of the UNI standard
10893:2000.
Diffusion, modification or use of this manual for own aims is
Diffusion, modification or use of this manual for own aims is
forbidden.
The manual uses symbols which call the reader's attention
The manual uses symbols which call the reader's attention
to specific points to facilitate its use.
to specific points to facilitate its use.
It includes all technical, operating, shutdown, maintenance,
It includes all technical, operating, shutdown, maintenance,
spare parts and safety information.
spare parts and safety information.
In case of doubts on the correct interpretation of the
In case of doubts on the correct interpretation
instructions, please contact our technical service to obtain
instructions, please contact our technical service to obtain
the required clarifications.
Operations which are potentially hazardous for the
Operations which are potentially hazardous for the
operator are highlighted with this symbol.
operator are highlighted with this symbol.
Such operations can cause serious injury.
Such operations can cause serious injury.
Operations requiring special attention are highlighted with
requiring special attention are highlighted with
this symbol.
Such operations shall be carried out correctly to avoid
Such operations shall be carried out correctly to avoid
causing damage to objects or to the surrounding
causing damage to objects or to the surrounding
environment. This symbol also highlights information to
environment. This symbol also highlights information to
which special attention must be pa
which special attention must be paid.
| AIR-
-NEX 9380/9480 | 5 en
equipment maintenance can
. The equipment contains
the
the
equipment
equipment
before
before
The safety valve opens when the
Switches
Switches
the
the
equipment
equipment
off
off
by
by

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Air-nex 9480

Table of Contents