Operating Instructions
Constant Fan button (On some models)
In Cooling or Dry mode, press the button for 3 seconds to turn on or off the constant fan
function. When the function is turned on, the constant fan light will illuminate, identifying
the fan continuous run for cooling. When the function is turned off, the constant fan light
will go out, identifying the fan cycle run with compressor stop.
FRESH operation (on some models)
Press MODE and DOWN (-) buttons at the same time for 3 seconds to initiate FRESH feature
and the FRESH light illuminates on some models, the LED DISPLAY shows 'On' for 3 seconds.
The ion generator is energized and will help to purify the air inside. Press it for 3 seconds again
to stop the FRESH feature and the FRESH light turn dark on some models, the LED DISPLAY
shows 'OF' for 3 seconds for some units.
SLEEP/ECO operation
This feature can ONLY be activated from the remote control. To activate SLEEP feature, the
set temperature will increase (cooling) or decrease (heating) by 1°C/2°F (or 1°F) in 30 minutes.
The set temperature will then increase (cooling) or decrease (heating) by another 1°C /2°F
(or 1°F) after an additional 30 minutes. This new temperature will be maintained for 7 hours
before it returns to the originally selected temperature. This ends the Sleep mode and the unit
will continue to operate as originally programmed.
Note: This feature is unavailabe under FAN or DRY mode.
FOLLOW ME/TEMP SENSING feature (on some models)
This feature can ONLY be activated from the remote control. The remote control serves as
a remote thermostat allowing for the precise temperature control at its location. To activate
the Follow Me/Temp Sensing feature, point the remote control towards the unit and press the
Follow Me/Temp Sensing button. The remote control will send this signal to the air conditioner
until the Follow Me/Temp Sensing button is pressed again. If the unit does not receive the
Follow Me/Temp Sensing signal during any 7 minute interval, the unit will exit the Follow Me/
Temp Sensing mode.
Note: This feature is unavailable under FAN or DRY mode.
AUTO-RESTART
If the unit shuts off unexpectedly due to a power cut, it will restart with the previous function
setting automatically when the power resumes.
AIR FLOW DIRECTION ADJUSTMENT
Adjust the air flow direction manually:
· The louver can be set to the desired position manually.
· Do not place any heavy objects or other loads on the louver, doing so will cause damage to
the unit.
· Ensure the louver is fully opened under heating operation.
· Keep the louver fully opened during operation.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted for at least 3 minutes. This is to protect the
unit. Operation will automatically start after 3 minutes.