Download Print this page

IDEAL APP Power Drawer Assembly Instructions

Advertisement

Quick Links

Assembly Instructions for 75 amp and 35 amp Power Drawer Series
These assembly instructions include the instructions for wire termination, contact insertion and extraction,
pcb mount, and panel mounting of the Anderson Power Products middle and lower drawer connectors.
Available Tools:
Contact Insertion/Removal Tool
Crimp Tool
#20-#8 awg
Wire Termination:
Anderson Power Products recommends the following tools for wire termination. Crimping by other means
may produce high resistance joints:
1. Strip the wire according to the table below:
2. Place the contact mating end first into the crimp tool. Insert the wire all the way into the open crimp
barrel making sure that all strands are included. Squeeze the tool handles until the cycle completes
and the tool handles release. Remove the wire and crimped contact.
Contact Insertion:
The Anderson Drawer connectors have pre-loaded contact retention clips in the housing. The contacts
are loaded into the housing from the bottom. Line up the contact with the appropriate hole in the
connector. Insert the mating end of the connector into the hole first. Slide the insertion/extraction tool
over the wire and butt it against the shoulder of the contact. Push the contact into the housing until it
bottoms out. Squeeze the tool slightly and remove. Give a gentle pull on the wire to ensure that the
retention clips are fully engaged.
1S6416 Rev. 1 ECN 2021-0124
Wire Size AWG
Type
Crimp Tool
12 to 20
turret head/locator
Crimp Tool
8
turret head
locator
Contact Size
Wire Size AWG
#20
#20
#16
#16
#12
#14-#12
#8
#10-#8
MIL-STD
M22520/1-01
M22520/1-02
M22520/23-01
M22520/23-02
M22520/1-09
Length
±.020 (.51)
In
mm
.210
5.33
.270
6.86
.270
6.86
.500
12.70
Page 1 of 5

Advertisement

loading

Summary of Contents for IDEAL APP Power Drawer

  • Page 1 Assembly Instructions for 75 amp and 35 amp Power Drawer Series These assembly instructions include the instructions for wire termination, contact insertion and extraction, pcb mount, and panel mounting of the Anderson Power Products middle and lower drawer connectors. Available Tools: Contact Insertion/Removal Tool Crimp Tool #20-#8 awg...
  • Page 2 Contact Removal: Removal of the wire crimped contacts from the housing requires a contact removal tool. The contact removal tools are as follows: #20 contact M81969/14-11 #12 contact M81969/14-04 #8 contact M81969/14-12 To remove a contact, squeeze the insertion/extraction tool, insert it into the appropriate hole from the bottom side of the connector, then allow the tool to expand out.
  • Page 3 Panel Cut-out Dimensions: The sketch below shows the suggested panel cut-out dimensions for the Middle and Lower Drawer. 1S6416 Rev. 1 ECN 2021-0124 Page 3 of 5...
  • Page 4: Pcb Mounting

    PCB Mounting: When mounting to a PCB, the standoffs on the bottom of the connector should be seated directly on the board. The standoffs will allow a .020 (.51) gap between the bottom flange of the connector and the board. This gap is essential for proper soldering.
  • Page 5 1S6416 Rev. 1 ECN 2021-0124 Page 5 of 5...