Page 1
Assembly Instructions for 75 amp and 35 amp Power Drawer Series These assembly instructions include the instructions for wire termination, contact insertion and extraction, pcb mount, and panel mounting of the Anderson Power Products middle and lower drawer connectors. Available Tools: Contact Insertion/Removal Tool Crimp Tool #20-#8 awg...
Page 2
Contact Removal: Removal of the wire crimped contacts from the housing requires a contact removal tool. The contact removal tools are as follows: #20 contact M81969/14-11 #12 contact M81969/14-04 #8 contact M81969/14-12 To remove a contact, squeeze the insertion/extraction tool, insert it into the appropriate hole from the bottom side of the connector, then allow the tool to expand out.
Page 3
Panel Cut-out Dimensions: The sketch below shows the suggested panel cut-out dimensions for the Middle and Lower Drawer. 1S6416 Rev. 1 ECN 2021-0124 Page 3 of 5...
Page 4
PCB Mounting: When mounting to a PCB, the standoffs on the bottom of the connector should be seated directly on the board. The standoffs will allow a .020 (.51) gap between the bottom flange of the connector and the board. This gap is essential for proper soldering.