Power Supply; Power Supply Pins - Quectel BC65 Hardware Design

Nb-iot module
Table of Contents

Advertisement

The procedure of the modem entering PSM is as follows:
The modem requests to enter PSM in "ATTACH REQUEST" message during attach/TAU (Tracking Area
Update) procedure. Then the network accepts the request and provides an active time value (T3324) to
the modem and the mobile reachable timer starts. When the T3324 timer expires, the modem enters PSM
for a duration of T3412 (periodic TAU timer). Note that the module cannot request PSM when it is
establishing an emergency attachment or initializing the PDN (Public Data Network) connection.
When the module is in Deep Sleep mode, it will be woken up in either of the following cases:
After the T3412 timer expires, the module will exit from Deep Sleep mode automatically.
Pulling down PSM_EINT (falling edge) will wake up the module from Deep Sleep mode.
The timing of waking up the module from Deep Sleep mode is illustrated below.

3.6. Power Supply

3.6.1. Power Supply Pins

BC65 provides two VBAT pins for connection with an external power supply. The table below describes
the module's VBAT and ground pins.
Table 9: Power Supply Pins
Pin Name
Pin No.
VBAT
42, 43
GND
1, 10, 27, 34, 36, 37, 40, 41
BC65_Hardware_Design
VBAT
≥ 100 ms
PSM_EINT
VDD_EXT
Module
Deep Sleep
Status
Figure 4: Timing of Waking Up Module from Deep Sleep
Description
Power supply for the module
GND
NB-IoT Module Series
BC65 Hardware Design
Running
Min.
3.2
-
Typ.
Max.
Unit
3.8
4.2
V
-
-
-
21 / 55

Advertisement

Table of Contents
loading

Table of Contents