INSTALLATION INSTRUCTIONS

NOTE: Install the battery backup system when the
primary pump is not needed. Read instructions and
prepare all supplies before beginning installation.
1. Disconnect power to primary sump and remove
from sump pit.
2. Be sure the o-ring is on the discharge of the
backup pump and slip the included stainless
steel clamp over the pump discharge. Press the
backup pump into the tee. Be sure the o-ring
is completely inside the tee and not visible. Be
sure the slit on the tee is on the bottom when
the pump is installed. Tighten the clamp over
the tee to secure the backup pump.
3. Be sure the o-ring is on the check valve and
thread the check valve into the discharge of the
primary pump. Be sure the weep hole is still
visible and hand tighten.