Zoeller ProPak AQUANOT Spin 508/53 Installation Instructions Manual

Zoeller ProPak AQUANOT Spin 508/53 Installation Instructions Manual

Preassembled sump pump system with battery backup

Advertisement

Quick Links

NOTICE TO INSTALLER: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
PREASSEMBLED SUMP PUMP SYSTEM WITH BATTERY BACKUP
MODEL 508 - 12 V DC BATTERY BACKUP SYSTEM
Patent No. D740329
1. Make certain that the receptacle is within reach of the pump's power supply
cord. Do not use primary pump circuit. DO NOT USE AN EXTENSION CORD.
Extension cords that are too long or too light do not deliver sufficient voltage
to the pump motor, and they could present a safety hazard if the insulation
were to become damaged or the connection end were to fall into a wet or
damp area.
2. Make sure the pump electrical supply circuit is equipped with fuses or circuit
breakers of proper capacity. A separate branch circuit is recommended,
sized according to the National Electrical Code for the current shown on the
pump nameplate.
3. Testing for ground: as a safety measure, each electrical outlet should be
checked for ground using an Underwriters Laboratory listed circuit analyzer
which will indicate if the power, neutral and ground wires are correctly
connected to your outlet. If they are not, call a qualified, licensed electrician.
4. For Added Safety: Pumping and other equipment with a 3-prong grounded plug
must be connected to a 3-prong grounded receptacle. For added safety the
receptacle may be protected with a ground-fault circuit interrupter. When
a pump needs to be connected in a watertight junction box, the plug can be
removed and spliced to the supply cable with proper grounding. For added
safety this circuit may be protected by a ground-fault circuit interrupter. The
complete installation must comply with the National Electrical Code and all
applicable local codes and ordinances.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER
SOURCE BEFORE HANDLING. Single phase pumps are supplied with a 3-prong
grounded plug to help protect you against the possibility of electrical shock.
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN. The
3-prong plug must be inserted into a mating 3-prong grounded receptacle.
If the installation does not have such a receptacle, it must be changed to the
proper type, wired and grounded in accordance with the National Electrical
Code and all applicable local codes and ordinances.
6. The tank is to be vented in accordance with local plumbing code. Pumps
must be installed in accordance with the National Electrical Code and all
applicable local codes and ordinances. Pumps are not to be installed in
locations classified as hazardous in accordance with National Electrical
Code, ANSI/NFPA 70.
7 .
Risk of electrical shock. Do not remove power supply cord and
strain relief or connect conduit directly to the pump.
8 .
Installation and servicing of electrical circuits and hardware should
be performed by a qualified, licensed electrician.
9. Pump installation and servicing should be performed by a qualified person.
10. Risk of electrical shock. These pumps have not been investigated for use in
swimming pools and marine areas.
11. Prop65 Warning for California residents: Cancer and Reproductive Harm-
www.P65Warnings.ca.gov.
12. It is the owner's responsibility to check the battery and battery connection at
least once a month. Batteries contain acid and caution must be taken when
handling.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
AQUANOT
Spin
®
WITH 115 V AC POWERED SUMP PUMP
MODEL M53
INSTALLATION INSTRUCTIONS
SEE BELOW FOR
LIST OF WARNINGS
© Copyright 2020 Zoeller
508/53, 508/98
OR M98
®
CAUTION
1. Check to be sure your power source is capable of handling the voltage
requirements of the motor, as indicated on the pump name plate.
2. Vent hole. It is necessary that all submersible sump, effluent, and sewage
pumps capable of handling various sizes of solid waste be of the bottom
intake design to reduce clogging and seal failures. Vent holes should
be checked periodically for clogging. The 50 Series pumps have a vent
located in the pump housing opposite the float, adjacent to a housing lug.
Water stream will be visible from this hole during pump run periods.
3. Pump should be checked frequently for debris and/or build up which may
interfere with the float "on" or "off" position. Repair and service should
be performed by an Authorized Service and Warranty Center only.
4. Dewatering and effluent sump pumps are not designed for use in pits
handling raw sewage.
5. Maximum operating temperature must not exceed 130 °F (54 °C).
6. Do not operate a pump in an application where the Total Dynamic Head is
less than the minimum Total Dynamic Head listed on the Pump Performance
Curves.
7. For indoor use only.
8. DC emergency pumps are designed for handling clear water. Do not use
in septic tanks to pump effluent or sewage pits to pump sewage.
9. Repair and service of your DC backup system should be performed by
an Authorized Service and Warranty Center.
10. The installation of DC automatic backup pumps requires the use of a variable
level float switch for operation. It is the responsibility of the installing party,
to ensure that the float switch will not hang up on the pump apparatus
or pit peculiarities and is secured so the pump will turn "on" and "off".
It is recommended that the pit be 18" (45.7 cm) in diameter or larger to
accommodate both a primary and a DC backup pump.
NOTE: Pumps with the "UL" mark and pumps with the "US" mark are tested to UL Standard
UL778. CSA Certified pumps are certified to CSA Standard C22.2 No. 108.
This equipment has been tested and found to comply with the limits for a class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
- Reorient or relocate the module/ product.
- Increase the separation between the equipment and module/ product.
- Consult the dealer or an experienced radio/TV technician for help."
Co. All rights reserved.
®
Visit our website:
zoellerpumps.com
NOTICE: VENT HOLE FOR
CHECK VALVE SEE #2 IN
CAUTION SECTION BELOW
DATE INSTALLED:
MODEL NUMBER:
SEE BELOW FOR
LIST OF CAUTIONS
REFER TO WARRANTY ON PAGE 2.
FM3167
1220
Supersedes
0419

Advertisement

Table of Contents
loading

Summary of Contents for Zoeller ProPak AQUANOT Spin 508/53

  • Page 1 12. It is the owner’s responsibility to check the battery and battery connection at least once a month. Batteries contain acid and caution must be taken when handling. REFER TO WARRANTY ON PAGE 2. © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 2: Limited Warranty

    10. Vent gases and odors to the atmosphere through vent pipe. 4. Use full-size discharge pipe. 5. Basin must be in accordance with applicable codes and 11. Install Zoeller Pump Stand (Model 10-2421) under pump to provide a settling basin. specifications.
  • Page 3: Service Checklist

    If the above checklist does not uncover the problem, consult the factory - do not attempt to service or otherwise disassemble pump. Service must be performed by Zoeller Authorized Service Centers. Go to www.zoellerpumps.com/service stations to find the Authorized Service Centers in your area.
  • Page 4: Battery Selection

    5. Complete the final testing of your installation by ensuring the primary pump is still disconnected from power. Then, unplug the fit controller from the 115 V wall outlet. Run water into the sump © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 5: Troubleshooting Information

    Take proper safety precautions. Do not splash the (e) Push alarm reset switch. The alarm will go off. acid. (f) Pump will shut off after water level is lowered and the float drops to the off position. © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 6 © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 7: Float Switch

    GROUNDED POWER CORD LOCKING PIN MUST BE INSTALLED UNDER FLOAT ROD IN THIS LOCATION. 30 AMP FUSE DC PUMP HIGH WATER OPERATIONAL AQUANOT SPIN CONTROLLER ® ™ FIGURE 5 FIGURE 4 SK3187 SK3186 © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Page 8: Carbon Monoxide Detectors

    There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never become fully charged and may damage the charging circuits of the Control. It is for this reason that Zoeller Pump Company offers its own line of batteries.

This manual is also suitable for:

Propak aquanot spin 508/98

Table of Contents