Page 2
Should you require any années d’agréable usage. Pour tout soutien technique ou technical or warranty assistance, please visit us at: pour toutes questions sur la garantie, veuillez visiter notre site au : www.ad-waters.com 1 888 ADW-9336 www.ad-waters.com 1 888 ADW-9336 last revision:...
Page 3
DISTRIBUTED BY / DISTRIBUÉ PAR VALVE COMPONENTS COMPOSANTS DE LA VALVE Installation p.11 SPECS AT LARGE / SCHÉMA DES PIÈCES 1- ALT76061100: Deverter/Déviateur 2- ALT760705SS: Check valve / Valve d'arrêt 3- ALT760703: Cartridge holder/ manchon de cartouche 4 ALT76010100 + ALT76010200: Extension kit (sold separately) / Kit d’extension (vendu séparément) last revision: 19/11/2021...
Page 4
DISTRIBUTED BY / DISTRIBUÉ PAR BEFORE YOU START AVANT DE COMMENCER CAUTION: FOR BEST RESULTS, WE STRONGLY MISE EN GARDE: POUR OBTENIR UN RÉSULTAT OPTIMAL, RECOMMEND THE INSTALLATION OF THIS VALVE BE NOUS RECOMMANDONS FORTEMENT QUE L’INSTALLATION DE DONE BY A LICENSED PLUMBER. CETTE VALVE SOIT FAITE PAR UN PLOMBIER ACCRÉDITÉ.
DISTRIBUTED BY / DISTRIBUÉ PAR INSTALLATION How to Use the Plastic Protector Cap The valve is covered by a plastic protector cap. It can be used as a template for setting the depth of the valve in the wall. The finished wall can fall anywhere along the side of this plastic cap (Fig.1).
DISTRIBUTED BY / DISTRIBUÉ PAR INSTALLATION A Installing the valve Min [43.00] 1 11/16” Once the mixer location is determined, position the Max [67.00] 2 5/8” valve in between 2x4 studs inside the wall on a plywood backing for better support. (Fig. 3) Make sure the valve is level and at the right VALVE depth before securing it firmly in place.
DISTRIBUTED BY / DISTRIBUÉ PAR INSTALLATION Connecting the water Connect the hot and cold water inlets and the mixed water outlets (Fig. 5). The hot water must always be connected on the left side and the cold water on the right, as indicated on the valve body.
Page 8
DISTRIBUTED BY / DISTRIBUÉ PAR MAXIMUM TEMPERATURE SETUP AJUSTEMENT DE LA TEMPÉRATURE MAXIMALE AUTORISÉE The highest temperature needs to be set at or under 120°F (49°C). It can be adjusted as follows: remove the decorative cap (1), the set screw (2), the handle (3) and the dome cap (4) (Fig. 6). Pull out the temperature limiting ring (5) from the cartridge (6).
DISTRIBUTED BY / DISTRIBUÉ PAR MAINTENANCE ENTRETIEN To Service The Cartridge Remove all the components from (1) to (8). (Fig. 7). Then, shut off the 2 check valves (11) by turning them clockwise with a screwdriver. Unscrew the cartridge holder (9) and remove the cartridge (10).
Page 10
DISTRIBUTED BY / DISTRIBUÉ PAR * extension kit kit d’extention INSTALLATION OF EXTENSION KITS #ALT76010100 + #ALT76010200 (IF NEEDED) INSTALLATION DU KITS D'EXTENSION #ALT76010100+ #ALT76010200 (SI NÉCESSAIRE) Remove all the components from (1) to (8) (Fig. 8), discard the 2 screws (4). Then shut-off the two check valves (11) by turning them clockwise with a screwdriver.
AD Waters se réserve le droit de modifier les spécifications de ses produits sans avis ni This warranty is in lieu of and excludes all other warranties, conditions and obligation ainsi que de remplacer ou de retirer certains modèles.
Page 12
DISTRIBUTED BY / DISTRIBUÉ PAR last revision: 19/11/2021...